Heatilator • RBV4236/RBV4842 • 4048-210 • Rev S • 6/10
16
In addition to these framing dimensions, also reference the
following sections:
• Clearances and Mantel Projections (Sections 3.C. and 3.D.)
• Vent Clearances and Framing (Section 6)
A
A
A
C
B
B
1/2 in. (13 mm) min.
appliance
to combustibles
Alcove
Installation
C
Drywall
48 in.
(1219 mm)
max.
1 in.
(25 mm)
min.
A
B
C
in.
42
48
22
mm
10
6
7
121
9
559
in.
48
5
1-1/4
22
mm
121
9
1
3
27
559
Model #
RB
V
42
36
RB
V
4842
5
Framing and Clearances
A. Selecting Appliance Location
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Fig-
ure 5.1).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due
to high temperatures, the appliance should be located out
of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 5.1 Appliance Locations