02/04
4034-102 Rev F
3
HRV200PLUS INSTALLATION INSTRUCTIONS
C. ENGINEERING DATA
Efficient, Patented Aluminum Core
The cross-flow heat recovery core transfers heat between the intake and exhaust airstreams. The core removes easily for cleaning
or service.
Diagnostic LED
A diagnostic LED mounted on the side of the HRV200PLUS cabinet indicates normal and abnormal operating modes for efficient
system evaluation without having to open the door.
Supply and Exhaust Air Blowers
The supply and exhaust air flows are supplied by two forward curved blower wheels driven by a common, double shaft PSC blower
motor. Four field selectable blower speeds one high speed and three low speeds are available to meet specific installation
needs. The blower motor is rated at 120VAC, 1.4 Amps.
Air Filters
Air filters are supplied in both the exhaust and supply air streams. The filters are washable and easily removed for cleaning.
Automatic Defrost System
The HRV200PLUS is equipped with an automatic defrost feature utilizing heat from the Fresh Air Fireplace to defrost the HRV core.
As a warning feature, the electric ember bed will light for 15 seconds prior to ignition. Alternatively, a field installed defrost system
using recirculated indoor air to remove frost is available as an option.
Cabinet
Painted twenty gauge galvanized steel outer shell and aluminized inner liner sandwich ¾ (19mm) insulation to provide strength,
reduce heat loss and insure a corrosion free life.
Mounting
The HRV200PLUS comes supplied with four reinforced polyester straps which attach to the threaded inserts at each corner of the
case for easy installation and quiet operation.
Installed Weight
- 78 lbs. (35.4 kg)
Shipping Weight
- 84 lbs. (38 kg)