12
Heatilator • HEIR36-IFT, HEIR42-IFT, HEIR50-IFT Owner’s Manual • 2458-981 Rev. C • 2/17
H. Heat Management
Heat Output
Heat output may be controlled on HEIR models by adjusting
the “FLAME” setting on the remote control.
G. Appliance Break-In
Follow the initial break-in procedure below to cure the
materials used to manufacture the
fi
replace and the
fnishing materials around it.
• The fireplace should be run three to four hours
continuously on high.
• Turn the
fi
replace off and allow it to cool completely.
• Remove
fi
xed glass assembly. See Section 4.B.
• Clean
fi
xed glass assembly. See Section 4.
• Replace the
fi
xed glass assembly and run continuously
on high an additional 12 hours.
Note:
The IPI system has a safety feature that automatically
shuts down the fireplace after 9 hours of continuous
operation without receiving a command from the remote
control. If this occurs, restart the appliance.
NOTICE! Open windows for air circulation during
fi
re-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.