16
20356 Rev R
08-03
G136 SERIES INSTALLATION INSTRUCTIONS
7. Wiring
Note:
This appliance must be electrically wired and
grounded in accordance with local codes or, in the ab-
sence of local codes, with
National Electric Code ANSI/
NFPA 70-latest edition
or
CSA C22.1 Canadian Electri-
cal Code, Part 1 Safety Standard for Electrical Instal-
lations
. This appliance is not intended for use with a ther-
mostat. The addition of a thermostat will void the warranty
and may create a fire hazard.
Note:
Field installed wires must be grounded. Two 110V
AC supplies are required if an optional fan kit is to be
used.
Figure 14 - Electronic Ignition Wiring Diagram
14-3 with Ground Romex is the recommended wiring to the appliance
junction box. This allows each outlet to power the appliance and fan
independently. See the inset of for a detailed picture of the junction box,
which is optional for standing pilot appliances.
3) Optional Accessories Requirements
Optional accessories may be added now or
at a later date, however, wiring should be
done now to avoid significant wall
reconstruction. Two black wires are for the
optional 110 volt switched fan. The optional
fan kit requires a separate 110V AC supply
to the appliance junction box for operation,
as shown in Figure 14. In line with this
junction box, you must have an ON/OFF
switch or a fan motor speed control. No
additional 110V AC supplies are required for
the fan motor speed control or the remote
control. One black wire and the one white
wire are for supplying 110 volt for ignition and
for the optional 110 volt switched remote
control. Wiring diagrams are provided with all
accessories.
Note:
Extended lengths of wire will reduce millivolt
readings and may cause appliance shutdowns.
a. Electronic Ignition
1) Appliance Requirements
This appliance requires a 110V AC supply
from a remote wall switch to the appliance
junction box for operation. A wiring diagram
is shown in Figure 14.
2) Remote Wall Switch
Position the junction box in the desired place
on the wall. Run the provided wire from the
junction box. Connect it to a wall switch and
mount the wall switch inside the junction box.