G136 SERIES INSTALLATION INSTRUCTIONS
Note:
The appliance and its manual shutoff valve must
be disconnected from the gas supply piping system dur-
ing any pressure testing of that system at test pressures
in excess of 1/2 psi (3.5 kPa). The appliance must be
isolated from the gas supply piping system by closing
its manual shutoff valve during any pressure testing of
the gas supply piping system at test pressures equal to
or less than 1/2 psi (3.5 kPa).
Note:
Although each appliance is leak tested in the fac-
tory, it is mandatory during the first burn for you to check
for leaks. These may occur due to handling, shipping,
installation and the like and are beyond the control of
Hearth & Home Technologies. Every joint, including the
valve, pilot, fittings, etc. must be checked.
Figure 12 - Spring Hinges on Control Access Panel
Figure 13 - Control Access Panel Removal
Figure 10 - Gas Line
Figure 11 - Open Control Access Panel
WARNING!
This valve has been preset at the factory. Altering
settings may result in fire hazard or bodily injury.
6. Control Access Panel Removal
To open the control access panel, gently lift upward and
pull on the upper outside edges of the panel as shown
in Figure 11. The top part of the control access panel
will rotate downward.
Two spring hinges secure the lower portion of the
control access panel into place. See Figure 12. Simply
pull the hinges toward the center of the control access
panel and then pull out the entire control access panel
See Figure 13. To replace the control access panel,
reverse this process.