14
Heatilator • ECO-ADV-WS22 • 7057-128D • September 15, 2011
7.
Snap Disc Location
If you fi nd the blower coming on and off at undesirable
temperatures, relocate the snap disc to another location
in the designated zone on the back of the appliance.
Figure 14.2.
There is a manual over-ride switch to
deactivate the snap disc, if necessary.
See page 40
for location of over-ride switch.
M. Blower Operating Instructions
Blower
Snap Disc
Figure 14.1
Figure 14.3
N. Clear Space
• Do NOT place combustible objects within 4 ft (1.2 m) of
the front of appliance. See
Figure 14.3
.
WARNING! Do NOT place combustible objects in front
of the appliance. High temperatures may ignite clothing,
furniture or draperies.
• Mantel - avoid placing candles and other heat-sensitive
objects on mantel or hearth. Heat may damage these
objects.
NOTE:
If your wood appliance is equipped with an optional
blower, you should follow these guidelines:
Burn Rate
Air Control
Handle Up = Open
Handle Down = Closed
Figure 14.2 - Snap Disc Location
Maintain 4 ft. (1.22m) clearance to
combustible in front of appliance
1.
Initial (cold) startup:
Raise
the Burn Rate Air Control
all the way up to the High setting.
The blower tends to
cool the appliance. Leave the blower off until the burn is
well established, i.e., 30 minutes.
2
. High Burn Setting:
Raise
the Burn Rate Air Control all
the way up to the High setting.
The blower may remain
on.
3.
Medium or Medium High Burn Setting:
Burn Rate Air
Control is closed then opened to 1 inch (pull up). The
blower may remain on.
4.
Medium
Low Burn Setting:
Burn Rate Air Control is
closed then opened to 1/4 inch to 1/2 inch (pull up).
Leave the blower off for the fi rst 30 minutes until the burn
is well established.
5.
Low Burn Setting:
Burn Rate Air Control is closed
(down position). Leave the blower off for the fi rst 30 min-
utes until the burn is well established.
NOTE:
For maximum effi ciency and lowest emissions,
when operating the blower in either the automatic or
manual setting for the low and medium low burn settings
leave the blower off until the burn is well established, i.e.,
30 minutes,
When reloading the appliance, raise the Burn Rate Air
Control all the wall to the High setting for 5 to 15 minutes
before setting to the desired burn rate.
6. The blower is equipped with a rheostat (speed control).
The highest blower speed is obtained by turning the
rheostat on, then adjusting back towards “OFF” as far
as possible without turning the blower off. For a low
blower speed, turn the control knob clockwise as far as
possible