Page 14
July 12, 2006
Heat & Glo · Mission Bay · 250-7512F
FOLD STRAP
HERE
WALL THIMBLE COVER/CEILING
FIRESTOP AS REQUIRED BY
LOCAL JURISDICTION
1/4 in. (6mm)
STRAP
SHEET METAL SCREW
WALL
THIMBLE
Figure 5.9
Burn Risk.
•
Local codes may require installation of a cap
shield to prevent anything or anyone from
touching the hot cap.
WARNING
WARNING
Do NOT connect a pipe section to a termination cap without
using the telescoping flue section found on the termination cap.
Fire Hazard.
Exhaust Fume Risk.
Impaired Performance of Appliance.
WARNING
• Ensure vent components are locked together correctly.
• Pipe may separate if not properly joined.
Note:
The attachment from the vent pipe to the vent
termination cap must be sealed with silicone. Termination
caps shall not be recessed into a wall or siding.
Step 1.
Check the installation instructions for required 1 in. (25mm)
clearances (air space) to combustibles when passing
through ceilings, walls, roofs, enclosures, attic rafters, or
other nearby combustible surfaces. See page 17,
Figure
5.16.
Check the instructions below for maximum vertical rise
of the venting system, and any maximum horizontal offset
limitations. All offsets must fall within the set parameters of
the vent graph (
Figure 5.2
) located on page 11.
NOTE:
Maximum vertical rise allowable is 35 ft. (11m),
Figure 5.11
, on the next page.
NOTE
: Maximum number of 45° elbows permitted for a
vertical installation is eight, provided their installation
does not decrease maximum allowable horizontal run (as
specified by vent graph, on page 11).
G. Vertical Termination
1. Direct Vent Pipe
Figure 5.10
VERTICAL
TERMINATION CAP
USE PART
#SLK-991DA
STORM COLLAR
FLASHING
FIRESTOP
PIPE LENGTH
SUPPORT BOX