background image

Page 2

Heat & Glo · Mission Bay · 250-7512F

                July 12, 2006

Read this manual before installing or operating this appliance.

Please retain this owner's manual for future reference.

Congratulations

Congratulations on selecting a Heat & Glo gas appliance - an 

elegant and clean alternative to wood burning appliances.  

The Heat & Glo gas appliance you have selected is designed 

to provide the utmost in safety, reliability, and efficiency.

As the owner of a new appliance, you'll want to read and 

carefully  follow  all  of  the  instructions  contained  in  this 

Owner's Manual

. Pay special attention to all Cautions and 

Warnings.

This Owner's Manual should be retained for future reference. 

We  suggest  that  you  keep  it  with  your  other  important 

documents and product manuals.

The information contained in this 

Owner's Manual

, unless 

noted  otherwise,  applies  to  all  models  and  gas  control 

systems.

Your new Heat & Glo gas appliance will give you years of 

durable  use  and  trouble-free  enjoyment.  Welcome  to  the 

Heat & Glo family of gas appliance products!

SAMPLE OF RATINGS LABEL

LOCATION:  Attached to rear of appliance

Manufactured 

Date

Serial Number

Model Name

Test Lab & 

Report No.

F-

Alcove  height

Hauteur De

l’Alcôve

A*

A*

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER

L’ÉTIQUETTE

Made in U.S.A. /  Fait Aux États-Unis

MINIMUM CLEARANCES TO COMBUSTIBLES

ESPACE MINIMUM AUX COMBUSTIBLES

Minimum  clearances required from combustible

construction for all appliance surfaces.

Espaces minimum exigés de la construction combustible

aux surfaces de l’appareil.

A. Rear of side panel to side wall

10” (254 mm)

           Du mur du poêle au coté du mur

A*. In an Alcove

10” (254 mm)

           Dans l’alcôve

B. Rear of control box to back wall

2” (51 mm)

           Le contrôle arrière au mur arrière

C. Flue pipe to back wall

6” (152 mm)

           Du tuyau de cheminée au mur arrière

D. Rear corner of stove top to side wall

2” (51 mm)

           Du coin arrière du poêle au mur de coté

E. Min. Floor to ceiling height (std. room)

84” (2134 mm)

           Hauteur minimum du plancher au plafond (pièce standard)

F. Flat surface on top of stove to alcove ceiling

19” (483 mm)

           Du dessus du poêle au plafond de l’alcôve

G. Maximum alcove depth

36” (914 mm)

           Profondeur maximum de l’alcôve

H. Minimum alcove width

40” (1016 mm)

           Largeur minimum de l’alcôve

250-7531

MODEL / MODÈLE: MISSION B AY

VENTED GAS FIREPLACE HE ATER

FOURNAISE  AU GAZ AVEC VENTILATION

NOT FOR USE WITH SOLID FUE L /

NE PAS UTILISER AVEC LE COMBUSTIBLE

SOLID E

Keep burner and control compartment clean. See installation and operating instructions accompanying this appliance./Gardez le brûleur et le compartiment de

contrôle propres. Vérifiez les instructions d’installation et d’opération qui accompagnent cet appareil.

This vented gas fireplace heater is not for use with air filters. / Cet appareil de chauffage au gaz n’est pas pour l’usage avec des filtres d’air./Due to high surface

temperatures, keep children, clothing and furniture away. / Du aux surfaces de températures élevées, gardez les enfants, les vêtements et les meubles à distance

éloignée.

ELECTRIC AL SUPPLY / FOURNITUR E ÉLECTR IQUE: 120 Volts, 1.2 Amps, 60 H

z

This applianc e mus t be properl y connecte d to a ventin g syste m in accordanc e with the manufacturer' s installatio n instructions./Ce t apparei l doit être correctemen t raccord é à un systèm e d'évacuation , conformémen t auz instruction s

du fabricant.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owne r’s manual

for details. This appliance is not convertible for use with other gase s, unless a certified kit is used./Cet appareil doit être utilisé seulement avec le gaz indiqué sur l’étiquette enregistrée et peut être installé dans une maison mobile

en place permanente dans les endroits permis par les codes locaux. Voyez le manuel du propr iétaire pour des détails supplémentaires. Cet appareil ne doit pas être converti avec d'autres gaz sans l’utilisation d’un ensemble de

conversion certifié.

FAN TYPE VENTED CIRCULATOR / VENTILATEUR CIRCULATOIRE

Blower Electrical Rating / Évaluation du

Ventilateur  Électrique:

115 V., 1.5 Amps, 60 Hz, 150 Watt s

Thermal Efficiency / Efficacité Thermique*

84% NG (blower on / avec ventilateur allumé)

85% LP (blower on / avec ventilateur allu

mé)

* With Maximum horizontal length. / Avec longueur horizontale maximum

.

Repo rt No. / Rapport Nu mé ro

061-S-49-5

  SERIAL  NO .

APPROUVÉ POUR LE CANADA ET LES ÉTATS-UNIS:

ANSI Z21.88b-2001 / CSA 2.33b-M01 Fournaises au Gaz avec Ventilation, et les sections

applicable de UL 307b Appareils de Chauffage Au Gaz pour les Maisons Mobiles et

les Véhicules Motorisés, CAN/CGA 2.17-M91 “Gas Fired Appliances for use at High

Altitudes”. Cet appareil est manufacturé pour l’opération avec le Gaz Naturel. Pour

une conversion au gaz propane les pièces du Manufacturier #LPK-MB et ses

instructions doivent être utilisées. Cet appareil peut être utilisé dans une chambre à

coucher ou salle de séjour; au Canada, l’installation d’un thermostat à distance est

exigée.

WARNING:IMPROPERINSTALLATION,ADJUSTMENT, ALTERATION,SERVICEORMAINTENANCECANCAUSEINJURYORPROPERTYDAMAGE.REFERTO THEOWNER’SINFORMATIONMANUALPROVIDEDWITHTHISAPPLIANCE.FORASSISTANCEORADDITIONAL

INFORMATIONCONSULTA QUALIFIEDINSTALLER,SERVICEAGENCYORTHEGASSUPPLIER./AVERTISSEMEN

T: UNEINSTALLATION,UNAJUSTEMENT, UNEALTÉRATION,UNSERVICEOUUNENTRETIENINCORRECTSPEUVENTCAUSERDESDOMMAGESMATÉRIELS.

RÉFÉREZ-VOUS

 AU MANUELD’INFORMATION FOURNI AVEC CET APPAREIL. POUR ASSISTANCE OU DES INFORMATIONS SUPP

LÉMENTAIRES CONSULTEZ UN INSTALLATEUR

 QUALIFIÉ, UNE AGENCE DE SERVICE OU UN FOURNISSEUR DE GAZ.

CAUTION: HOT WHILE IN OPER

ATION. DO NOT TOUCH. SEVERE BURNS MAY RESUL

T. KEE P CHILDREN, CLOTHING, FURNITURE, GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY./ATTENTION: CHAUD LORQ

U’I L EST EN  OPÉR ATION. NE TOUCHEZ

PAS. DES B RÛLURES SÉVÈRES PEUVENT EN RÉSU

LTER. GARDEZ LES ENFANTS, LES

VÊTEMENTS, LES MEUBLES, L

A GAZOLINE ET LES AUTRES

 LIQUIDES DE VAPEUR INFLAMMABLE  ÊLOIGNÉS.

CAUTION: DO NOT OPER ATE THIS APPLIANCE WITH GLASS REMOVED, CRACKED OR BROKEN. REPLACEMENT OF THE PANEL(S) SHOULD BE DONE BY A LICENSED OR QUALIFIED SERVICE PERSON./ ATTENTION: CET APPAREIL NE DOIT PAS ÊTRE OPÉRÉ SI LA VITRE

EST BRI SÉE, CRAQUÉE OU ENLEVÉE. LE REMPLACEMENT DU

PANNEAU DOIT  ÊTRE FAIT PAR UNE PERSONNE LICEN

SÉE ET QUALIFIÉE.

APPROVED FOR CANADA AND USA TO:

ANSI Z21.88b-2001 / CSA 2.33b-M01 Vented Gas Fireplace Heaters, and applicable

sections of UL307b Gas Burning Heating Appliances for Manufactured Homes and

Recreational Vehicles, CAN/CGA 2.17-M91 “Gas Fired Appliances for use at High

Altitudes.” This appliance is manufactured for operation with Natural Gas. For

conversion to propane Manufacturer’s Part #LPK-MB and instructions must be used.

This appliance may be installed in a bedroom or bedsitting room; in Canada remote

thermostat installation is required.

HEARTH: A non-combustible hearth pad is not required. However, the

floor beneath the stove must be stable, level,and strong enough to support

the stove without a tipping hazard.

CHEMINÉE: Un coussinet non-combustible de cheminée n’est pas

exigé. Cependant, le plancher en dessous du poêle doit être droit, à

niveau et assez fort pour supporter le poêle sans le hasard de

basculer.

A division of Hearth & Home

Technologies

20802 Kensington Blvd, Lakeville, MN  55044

www.heatnglo.com

C

E

D

D

H

G

Not to scale

This appliance must be installed in accordance with the current Standard CAN/CSA Z240 MH, Mobile Housing or with Manufactured Home Construction and Safety

Standard, Title 24 CFR, Part 3280, or when such standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard. WARNING:

Do not operate the appliance until all sections have been assembled and installed in accordance with the manufacturer's instructions.

Installer l'appareil selon la norme CAN/CSA-Z240, Serie MM, Maisons mobiles ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard.

Si ces normes ne sont pas pertineutes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard. AVERTISSEMENT: Ne pas

utiliser l'appareil tant que toutes les sections n'ont pas ete assemblees et installees selon les instructions du fabricant.

For use with Natural Gas

For use with Propane

Usage  Au Gaz Naturel

Usage  Au Gaz Propane

0-2000 ’

0-2000’

Top Vent: Input Rate on “HI” (BTU/Hr)

30,000

30,000

Puissance Évaluée à “HI” (BTU/Hr)

Input Rate on “LO” (BTU/Hr)

22,000

23,000

Puissance Évaluée à “LO” (BTU/Hr)

Maximum Output (BTU/Hr)**

25,500

25,650

Puissance Maximum (BTU/Hr

Main Burner Orifice

.1065 (36 DMS)

.0635 (52 DMS)

Orifice du Brûleur Principal

Minimum Inlet Pressure (Inches W.C.)

4.5”

11”

Pression Minimum de la Valve (pouces W.C.)

Maximum Inlet Pressure (Inches W.C.)

7.0”

14”

Pression Maximum de la Valve (pouces W.C .)

Manifold Pressure on “HI” (Inches W.C.)

3.5” 10

Pression du Collecteur d’ Échappement à “HI” (pouces W.C.)

**Max Venting, Blower On

                                                                                    **

Ventilation Maximum, Ventilateur Allu

P.4.1-02 Canada Minimum pipe (

P.4.1-02 Le canada tuyau minimum)  66.40% NG / 67.81% LP

B

A

007

Date of Manufacture / Date du Manufacturier

2006 2007 2008

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

Jan

This appliance equipped only for altitudes 0-2000 ’ (0-610m) in USA; and in Canada for altitudes of 0-450 0’ (0-1370m). In USA for Altitudes above 200 0’, the vent

configuration, orifice, or combination of both may need to be changed. See Owne r’s Manual for information on making these changes.

This appliance must be installed in accordance with local codes, if any (and Commonwealth of Massachusetts approved); if none, follow  National Fuel Gas

Code ANSI Z223.1, or Canadian Installation Codes, CAN/CGA-B149  in Canada. Install and use only in accordance with manufacture r’s installation and operating

instructions.

NOTE: Have the gas supply line installed in accordance with local building codes by a qualified installer approved and/or licensed as required by the

locality. (In the Commonwealth of Massachusetts, installation must be performed by a licensed plumber or gas fitte

r.)

Cet appareil est équipé pour les altitudes de 0-2000 ’ (0-610m) aux États-Unis; et au Canada pour les altitudes de 0-4500 ’ (0-1370m). Pour les alti tudes au dessus

de 2000’ aux États-Unis, la configuration du ventilateu r, son orifice ou les deux peuvent possiblement avoir à être changé. Voyez le manuel du propr iétaire pour

les informations sur ces changements.

Cet appareil doit être installé en accord avec les codes locaux, s’il-y-a lieu (et approuvé par dans la République de Massachusetts); sinon lisez au National Fuel

Gas Code ANSI Z223.1, ou aux code courant d'installation Installez et utilisez en accords avec les instructions d’installation et d’opération du manufacturier.

REMARQUE: Le conduit gaz doit être installé conformément aux codes de construction locaux. L'installation doit être effectuée par un technicien qualifeé

et/ou muni d'une licence de manière à respecter les règlements municipaux. (Dans la République de Massachusetts, l'installation doit être effectuée par

un plombier ou un installateur

 d'appareils à gaz agrée. )

SA

MP

L

E

O-T L

Tested and

Listed by

Beaverton

Oregon USA

OMNI- Test Laboratories, Inc.

C

US

July 12, 2006

Summary of Contents for MISSION BAY

Page 1: ...sing property damage personal injury or death This appliance may be installed as an OEM installation in manufactured home USAonly ormobilehomeandmustbeinstalledinaccordancewith the manufacturer s instructions and the manufactured home construction and safety standard Title 24 CFR Part 3280 or Standard for Installation in Mobile Homes CAN CSA Z240MH This appliance is only for use with the type s of...

Page 2: ... APPAREIL POUR ASSISTANCE OU DES INFORMATIONS SUPP LÉMEN TAIRES CONSULTEZ UN INSTALLATEUR QUALIFIÉ UNE AGENCE DE SERVICE OU UN FOURNISSEUR DE GAZ CAUTION HOT WHILE IN OPER ATION DO NOT TOUCH SEVERE BURNS MAY RESUL T KEE P CHILDREN CLOTHING FURNITURE GASOLINE AND OTHER LIQUIDS HAVING FLAMMABLE VAPORS AWAY ATTENTION CHAUD LORQ U IL EST EN OPÉR ATION NE TOUCHEZ PAS DES B RÛLURES SÉVÈRES PEUVENT EN RÉ...

Page 3: ...ion 6 Gas Information A Fuel Conversions 22 B Gas Pressures 24 C Gas Connection 24 Section 7 Electrical Information A Recommendation for Wire 26 B Connecting to the Appliance 26 C Standing Pilot Ignition System Wiring 26 Section 8 Appliance Setup A Remove Shipping Materials 28 B Accessories 28 C Door Crown Installation 28 D Grille Installation 28 E Brick Installation 28 F Positioning the Logs 29 G...

Page 4: ...WARNING Do NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water Manufactured Home or Mobile Home installation may occur only after the home is site located and must conform with the Manufactured Home Construction and Safety Standard...

Page 5: ... vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS G Requirements for the Commonwealth of Massachusetts Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installa t...

Page 6: ...urface Remove log set and component pack from firebox Report to your dealer any parts damaged in shipment particularly the condition of the glass Read all of the instructions before starting the instal lation Follow these instructions carefully during the installation to ensure safety and benefit Pliers Gloves Hammer Framing Square Phillips Screwdriver Electric Drill Bits Flat Blade Screwdriver Safe...

Page 7: ... Risk Provide adequate clearance Around air openings To combustibles For service access Locate appliance away from traffic areas NOTE For actual appliance dimensions refer to Section 12 Fire Risk Locate and install appliance to all clearance specifications in manual WARNING It is permissable to place the appliance on carpet CAUTION Some carpet materials may be sensitive to radiant heat from the appl...

Page 8: ... 12 to 9 12 2 0 Over 9 12 to 10 12 2 5 Over 10 12 to 11 12 3 25 Over 11 12 to 12 12 4 0 Over 12 12 to 14 12 5 0 Over 14 12 to 16 12 6 0 Over 16 12 to 18 12 7 0 Over 18 12 to 20 12 7 5 Over 20 12 to 21 12 8 0 3 foot minimum in snow regions 12 X LOWEST DISCHARGE OPENING ROOF PITCH IS X 12 H MIN MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING VERTICAL WALL 2 FT MIN 2 FT TERMINATION CAP HORIZONTA...

Page 9: ...cations a vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and only permitted if veranda porch deck or balcony is fully open on a minimum of 2 sides beneath the floor or meets Note 2 NOTE 1 On private property where termination is less than 7 feet above a sidewalk driveway deck porch veranda or balcony use of a listed cap is ...

Page 10: ...h vertical and horizontal vent aspects when calculating the effects Use the rise for the vertical aspect and the run for the horizontal aspect See Figure 5 1 Two 45 elbows may be used in place of one 90 elbow On 45 runs one foot of diagonal is equal to 8 1 2 in 216mm horizontal run and 8 1 2 in 216mm vertical run A length of straight pipe is allowed between two elbows See Figure 5 1 Vertical Horiz...

Page 11: ...A single vertical to horizontal 90 elbow is already calculated into the allowable 15 ft 5m run Each additional 90 elbow reduces the maximum horizontal distance by 3 ft 914mm Example The use of three elbows would reduce the allowable horizontal run to 9 ft 3 1 2 elbows x 3 ft 6 ft 15 ft max 6 ft 9 ft max Notes The maximum horizontal vent run is 15 ft 5m when the vertical vent rise is 10 ft 3m Horiz...

Page 12: ... so they match and slide into the entry slots on the male ends see Figure 5 4 Push the pipe sections completely together then twist lock one section clockwise approximately one quarter turn until the two sections are fully locked The female locking lugs may not be visible from the outside They may be located by examining the inside of the female ends Fire Risk Explosion Risk Combustion Fume Risk U...

Page 13: ...uilt in The pilot hole will be 2 in 51mm closer to the bottom of the square than the top Using a framing square draw a 14 in x 14 in 356mm x 356mm square around the pilot hole See Figure 5 7 WOOD SCREW WALL THIMBLE PART HHW2 PART 841 0670 Preferred Figure 5 6 Step 5 Place the wall thimble cover over the pipe assembly and slide the appliance and vent assembly towards the wall carefully inserting th...

Page 14: ... caps shall not be recessed into a wall or siding Step 1 Check the installation instructions for required 1 in 25mm clearances air space to combustibles when passing through ceilings walls roofs enclosures attic rafters or other nearby combustible surfaces See page 17 Figure 5 16 Check the instructions below for maximum vertical rise of the venting system and any maximum horizontal offset limitati...

Page 15: ...m the roof to the hole previously drilled in the ceiling and mark the spot where the vent will penetrate the roof Determine if ceiling joists roof rafters or other framing will obstruct the venting system You may wish to relocate the appliance or to offset as shown in Figure 5 12 to avoid cutting loadbearing members Figure 5 11 Figure 5 12 35 ft 11m MAXIMUM Fire Risk Explosion Risk Maintain vent c...

Page 16: ... in the current CAN CGA B149 Installation Codes in Canada the National Fuel Gas Code NFPA 54 ANSI Z223 1 in USA or local codes Note that for steep roof pitches the vent height must be increased See Roof Pitch Table Figure 4 3 on page 8 In high wind conditions nearby trees adjoining rooflines steep pitched roofs and other similar factors can result in poor draft or down drafting In these cases incr...

Page 17: ... 3mm GREATER IN SIZE THAN PATTERN OF SUPPORT BOX AS IT IS PROJECTED ONTO ROOF LINE Figure 5 17 Step 1 Follow installation Steps 1 and 2 under vertical installation section pages 14 15 Step 2 Remove shingles or other roof covering as necessary to cut the rectangular hole for the support box Cut the hole 1 8 in 3mm larger than the support box outline Step 3 Lower the support box through the hole in ...

Page 18: ...re the four corners and the overlapping sections of the trim collar to the ceiling You may want to predrill the holes for the overlapped sections for ease of installation Figure 5 19 3 Class A Metal Chimney Figure 5 20 TERMIN ATION CAP PART SLK 991D A EXISTING ME TAL CHIMNE Y SYSTE M TOP ADAPTE R FLASHING 4 in 102mm FLEX PIPE RETRO CONNEC TOR DIRECT VENT PIPE Top Adapter Sheet Metal Screws Flex Pi...

Page 19: ...eet metal screws Step 7 The connection between the appliance and the retro connector may be completed with sections of direct vent pipe Step 1 Before cutting any holes assemble the desired sections of direct vent pipe to determine the center of the masonry penetration Step 2 Oncethecenterpointofthepenetrationhasbeendetermined cut a 6 in 152mm diameter hole in the masonry If the hole is too large t...

Page 20: ...to the top adapter using three sheet metal screws Figure 5 21 page 18 Step 6 Feed the flex liner through the flashing into the chimney Carefully feed the flex liner down the chimney to the bottom and out the opening in the masonry wall forming an angle to line up the flex liner with the vent opening on the appliance Step 7 If additional lengths of flex liner are needed to span the chimney height u...

Page 21: ...NING IN MASONRY WALL THREE MASONRY BOLTS NOT INCLUDED RETRO CONNECTOR FOUR MASONRY BOLTS NOT INCLUDED RETRO CONNECTOR WALL THIMBLE COVER Step 10 Slide wall thimble cover over retro connector and secure with masonry bolts Figure 5 30 If you have a framed wall in front of the masonry use wood screws to mount wall thimble cover to framed wall over retro connector and 10 in 254mm square framed opening...

Page 22: ...installed It is only necessary to remove the left brick panel for burner removal Loosen the shutter adjustment wingnut located underneath the appliance It is helpful to remove the nut completely Slide the shutter to the right closed position Figure 6 2 Lift the burner from the left side and slide left until free from the orifice receiver Remove from the firebox and handle with care Figure 6 4 Remove...

Page 23: ...ing screws A pressure regulator tower B and diaphragm C Figure 6 6 Ensure that the rubber gasket D is properly posi tioned and install the new HI LO pressure regulator assem bly to the valve using the new screws E supplied with the kit Tighten screws securely Reference torque 25 in lb Install the enclosed identification label F to the valve body where it can be seen Fill out the conversion label an...

Page 24: ...e pressure is greater than 1 2 psig NOTE A listed and Commonwealth of Massachusetts approved 1 2 inch 13mm T handle manual shut off valve and flexible gas connector are connected to the 1 2 inch 13mm control valve inlet If substituting for these components please consult local codes for compliance NOTE The gap between the supply piping and gas access hole may be plugged with non combustible insulat...

Page 25: ...ing appliance it will take a short time for air to purge from lines When purging is complete the appliance will light and operate normally Air only needs to be purged again if gas valve has been turned to the OFF position WARNING Fire hazard Do NOT change the valve settings This valve has been preset at the factory Changing valve settings may result in fire hazard or bodily injury WARNING Fire Risk...

Page 26: ...ermostat see individ ual thermostat instructions to ensure proper operation of appliance 4 Use low resistance thermostat wire for wiring from igni tion system to the wall switch and thermostat 5 Use the following chart for wire sizing 6 Keep wire lengths as short as possible by removing any excess wire length 7 Low voltage and 110 VAC voltage cannot be shared within the same wall box Wire Size Max...

Page 27: ...ng controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing Ignitor VALVE Thermopi le Gas Pilot Ignitor Thermocouple Red 28 in 711mm Switch ON OFF Red 28 in 711mm Shock hazard Replace damaged wire with type 105O C rated wire Wire must have high temperature insulation CAUTION ...

Page 28: ...pliance C Door Crown Installation D Grille Installation 2 Screws 2 Vis 2 Screws 2 Vis Figure 8 1 Remove door from appliance Remove existing black crown by removing the four screws indicated from the back side of the face and pull the crown off of the door Set the new plated crown in place reinsert and tighten screws Figure 8 2 To remove the original grille loosen the four screws from the left and ...

Page 29: ...h care as breakage can easily occur PLEASE NOTE Logs have been designed to work specifically with the burner of this appliance Exact placement will ensure proper operation of your gas appliance and reduce sooting Figure 8 6 The log set and brick panels are packed in the components box Figure 8 7 Insert rear log 1 onto log pan over stud on the left gently pulling log forward to the tab on the right...

Page 30: ... action may void the coverage provided by the owner s home insurance CAUTION All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the National Electric Code ANSI NFPA NO 70 current in the United States or with the current CSA C22 1 Canadian Electric Code in Canada WARNING DO NOT CONNECT 110 120 VAC WIRING TO THE GAS CONTROL VALVE OF THIS APPLIAN...

Page 31: ...ated inside the pedestal Secure the bracket assembly with the wing nut provided NOTE THE SWITCH BRACKET ASSEMBLY MUST BE INSTALLED SO THAT THE SENSOR SWITCH MAKES CONTACT WITH THE BOTTOM OF THE FIREBOX Connect the variable speed control and the temperature sensor switch to the short lead wires of the junction box by plugging in the male and female connectors See Fig 8 16 on the next page Fan Wirin...

Page 32: ...o Mission Bay 250 7512F BLOWER BLOWER RECEP TACLE BLACK WHITE WHITE GROUND GRN 110 120 VAC BLACK JUNCTION BOX BLACK TEMPER ATURE SENSOR SWITCH BLUE BLACK BLACK VARIABLE SPEED SWITCH GROUND WIRE BLACK BLACK BLACK WHITE Figure 8 16 ...

Page 33: ...To adjust the shutter loosen the wingnut Retighten the wingnut after adjustment K Glass Replacement Use only Door and GlassAssembly replacement as specified in Section 12 of this manual available from your dealer if any glass becomes broken in the Mission Bay 1 Remove grille slide grille out of slots in existing door 2 Remove existing door from appliance 3 Remove crown from existing door by removin...

Page 34: ...T use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water WARNING Remove all shipping materials from inside and or underneath the firebox Review proper placement of logs mineral wool Check the wiring Check the baffle adjustment Ensure that t...

Page 35: ...or of the appliance May need to remove face front first 5 Push in gas control knob slightly and turn clockwise to the OFF position Do not force 6 Wait five 5 minutes to clear out any gas Smell for gas including near the floor If you smell gas STOP Follow B of the safety information above If you don t smell gas go to the next step 7 Push gas control knob in and turn counterclockwise to the pilot po...

Page 36: ...during initial operation Smoke may set off smoke detectors Smoke and odors may be irritating to sensitive individuals CAUTION Prevent accidental appliance operation when not attended Unplug or remove batteries from remote control if absent or if appliance will not be used for an extended period of time Property damage possible from elevated temperatures CAUTION ISSUE SOLUTIONS Condensation on the ...

Page 37: ...he thermocouple connection at the gas valve is fully inserted and tight hand tighten plus 1 4 turn Disconnect the thermocouple from the valve place one millivolt lead wire on the tip of the thermocouple and the other meter wire on the thermocouple copper lead Start the pilot and hold the valve knob in If the millivolt reading is less than 15mV replace the thermocouple b Defective valve If the ther...

Page 38: ...ng exhaust gases back into the system Check for proper vent connection at flue collar and all vent joints c Horizontal vent improperly pitched The horizontal vent cap should slope down only enough to prevent any water from entering the appliance d Bad thermopile or thermocouple Replace if necessary e Improper vent cap installation Check for proper installation and freedom from debris or blockage 6 ...

Page 39: ...n by qualified technician recommended Check Condition of glass glass assembly and glass seal Obstructions of combustion and ventilation air Obstructions of termination cap Burner ignition and operation Burner air shutter adjustment Gas connections and fittings Clean Glass Air passageways grilles control compartment Burner burner ports Risk of Fire Delayed ignition or explosion Exposure to combustion...

Page 40: ...ration Sand and repaint as neces sary 2 Replace appliance if firebox has been perforated Burner Ignition and Operation 1 Verify burner is properly secured and aligned with pilot or igniter 2 Clean off burner top inspect for plugged ports corrosion or deterioration Replace burner if necessary USE CAUTION WHEN CLEANING HANDLING CERAMIC BURNER 3 Replace ember material with new dime size and shape piec...

Page 41: ...imensions are actual appliance dimensions Use for reference only For clearances to combustibles refer to Section 3 Location Inches Millimeters Location Inches Millimeters A 22 1 2 570 E 29 1 8 740 B 10 1 8 257 F 16 3 8 415 C 18 3 4 476 G 17 7 16 445 D 7 3 4 197 Figure 12 1 Appliance Dimensions A B C D E F G ...

Page 42: ...5mm 6 1 2 in 165mm 6 5 8 in 168mm 17 24 in 432 610mm 11 3 4 in 298mm 5 3 4 in 146mm 6 5 8 in 168mm 6 3 8 in 162mm 6 1 2 in 165mm 9 5 8 in 244mm 6 5 8 in 168mm 6 1 2 in 165mm 6 3 8 in 162mm 9 5 8 in 244mm SL 06D SL 12D SL 17 24D SL17 24D SL 45D SL 90D 8 3 4 in 222mm 12 17 in 305 432mm 35 3 4 in 908mm 23 3 4 in 603mm 47 3 4 in 1213mm SL 09D SL 48D SL 36D SL 24D SL 12 17D SL 12 17D ...

Page 43: ...anger 950 Vinyl Protector Kit SL Pipe DRC RADIUS Decorative Radius Cover HTI DV WT Wall Thimble 844 9550 Slim Line Wall Thimble TERMINATION KITS SLK 01TRD Trapezoid Termination Kit 7 3 4 inch 11 inch 2 Firestops SLK 991DA Vertical Termination Cap High Wind 970D Horizontal Termination Kit includes 904B 930D SLK 01TRD SLK SNKD Snorkel Kit LINK STOVE Adapter Kit includes 30 ft of 4 inch flex apapters...

Page 44: ... 35 Burner Pan 6 Pilot Assembly NG 21 Valve Gas 36 Burner Support Kit Left and Right 7 Pilot Bracket 22 Extension Knob S I T ON OFF 37 Burner Assembly 8 Baffle Hangar 23 Valve Cover 38 Grille 9 Bulkhead 24 Dashboard Label 39 Door Assembly 10 Bulkhead Stop 25 Extension Knob S I T HI LO 40 Glass Assembly 3 Piece 11 Blower Bracket 26 Switch Rocker ON OFF 41 Door Crown 12 Blower Housing 27 Valve Bracke...

Page 45: ...0 37 Burner Assembly BRNR MB 35 Burner Pan 474 0080 36 Burner Support Kit Left and Right 842 5190 Component pack includes warranty card ON OFF valve mineral wool touch up paint and manual 479 5120 17 Curtain Mount Left or Right 479 0110 16 Curtain Side Left or Right 479 0150 24 Dashboard Label 250 6171 39 Door Assembly DOOR MB 41 Door Crown Matte Black 479 5080 30 DV Adapter 6 5 8 in 7000 162 Elec...

Page 46: ...iver SMART STAT HNG HNG Smart Batt Remote 2 Battery receiver SMART BATT HNG Blower Assembly GFK 160A Glass Assembly GLA MB Item Part Description Alphabetical Order SKU Pedestal Assembly 479 5020 5 Pedestal Base 479 0060 2 Pedestal Door 474 0190 4 Pedestal Riser 479 0080 6 Pilot Assembly NG 842 4940 7 Pilot Bracket 474 0100 Pilot Injector LP 200 2630 Pilot Orifice LP 063 17236 Pilot Orifice NG 106 19...

Page 47: ...h the Product or added thereafter are NOT covered by this warranty unless expressly authorized and approved by HEAT GLO in writing 6 Any damages caused by environmental conditions inadequate ventilation or drafting caused by tight sealing construction of the structure air handling devices such as exhaust fans or forced air furnaces or other such causes are not covered by this warranty 7 This warra...

Page 48: ...instructions included Read understand and follow these instruc tions for safe installation and operation Leave this manual with party responsible for use and operation This product may be covered by one or more of the following patents United States 4593510 4686807 4766876 4793322 4811534 5000162 5016609 5076254 5113843 5191877 5218953 5263471 5328356 5341794 5347983 5429495 5452708 5542407 560107...

Reviews: