Heat & Glo • 6X-AU Installation Manual • 2508-980 Rev. C
• 3/18
10
B. Clearances to Combustibles
When selecting a location for the appliance it is important
to consider the required clearances to walls (see Figure
3.3).
WARNING! Risk of Fire or Burns!
Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be lo-
cated out of traffic and away from furniture and draperies.
NOTICE:
Illustrations reflect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure 3.3 Appliance Locations
1/2 IN.
REAR VENT,
HORIZONTAL TERMINATION
TWO ELBOWS
REAR VENT
NO ELBOWS
REAR VENT
ONE ELBOW
ALCOVE
INSTALLATION
TOP VENT
ONE 90º ELBOW
A
B
C
B
E
B
B
B
D
D
F
G
H
D
A
D
NOTE: THE REAR STANDOFF MAY NEED
TO BE REMOVED WHEN VENTING AT 45º
Refer to Section 10.B for mantel and wall projection information.
Consider the mantel or cabinet system to be installed and comply with the
necessary requirements for elevated hearth. Refer to instructions included
with cabinet system.
A
B
C
D
E
F
G
H
6X-AU
in.
51
42
72
56-5/8
See Section
10.B. Mantel
Projections
22
17-3/4
8
mm
1295
1067
1829
1438
559
451
203
NOTICE:
Additional clearance are required for Heat-Zone
®
-240V
installations. Provisions must be made in advance to ensure fit within the
framing.