31
Heat & Glo • 6X-AU Installation Manual • 2508-980 Rev. C
• 3/18
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
NOTICE:
Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.
A. Vent Collar Preparation
6
Appliance Preparation
Top Vent
Figure 6.1 (Generic Appliance Shown)
Cut the seal ap
strap across the rectangles next to the disk. For rear vent,
skip this step.
Figure 6.2 (Generic Appliance Shown)
Remove the
white gasket material covering the seal cap.
Figure 6.4 (Generic Appliance Shown)
Remove the in-
sulation basket and white insulation from the center vent
pipe.
Figure 6.5 (Generic Appliance Shown)
Remove the
insulation from the outer vent pipe. For rear venting there
is no insulation in the outer vent pipe.
NOTICE:
Once the seal cap has been removed it CANNOT
be reattached.
Figure 6.3 (Generic Appliance Shown)
Remove the seal cap.