13
Installation Manual
PART 3: PHOENIX SOLAR WATER HEATER INSTALLATION
(CONT’D)
VALVE
INTAKE AIR
SOLAR AIR RELEASE VENT
EXCHANGER RETURN
TANK
AUXILIARY
INLET
CONNECTION
CONDENSATE
TEMPERATURE AND PRESSURE
VENT
EXHAUST VENT
BALL VALVE
LINE
RELIEF VALVE
TEMPERATURE/PRESSURE GAUGE
PHOENIX SOLAR PIPING WITH AIR HANDLER
DRAIN VALVE
EXCHANGER SUPPLY
GAS
EXPANSION
TEMP/PRESSURE
LINE
AIR
TO SUITABLE OPEN DRAIN
MIXING VALVE
C
SOLAR HEAT
TANK SENSOR
HOT
RE-CIRCULATED
CHECK
OUTLET
ANTI-SCALD
SOLAR COLLECTOR SENSOR
CIRCULATOR
RELIEF VALVE
COPPER DISCHARGE LINE
PREVENTER
BACKUP HEAT
WATER
SUPPLY
COLD WATER INLET
HECK WITH AIR HANDLER
HOT WATER
CLOSED LOOP
BACKFLOW
FILL VALVE
EXPANSION
BALL VALVE
EXCHANGER
SOLAR COLLECTOR
(see note 7)
BALL VALVE
HANDLER *
BALL VALVE
CIRCULATOR
TANK
AUXILIARY
COLD
WATER
MANUFACTURER FOR PROPER SIZING
CONNECTION
SOLAR HEAT EXCHANGER
*
SOLAR HEAT
DRAIN VALVE
OUTLET
SOLAR
CONTROLLER
TEMPERATURES.)
(CIRCULATORS WITH INTEGRAL FLOW CHECKS ARE NOT TO BE USED IN SOLAR SYSTEMS DUE TO EXTREME
NOTES:
1. THIS DRAWING IS MEANT TO SHOW A SYSTEM PIPING CONCEPT ONLY. THE INSTALLER IS RESPONSIBLE FOR ALL EQUIPMENT AND DETAILING
BY LOCAL CODES.
2. ANTI-FREEZE, NON- POTABLE HEAT TRANSFER FLUID SHALL BE USED FOR THE SOLAR HEAT EXCHANGER CIRCUIT ONLY. NEVER NTRODUCE
ANTI-FREEZE SOLUTION TO ANY OTHER CONNECTION OTHER THAN THE SOLAR HEAT EXCHANGER.
3. IF THERE IS A CHECK VALVE ON THE COLD WATER FEED LINE, A THERMAL EXPANSION TANK SUITABLE FOR POTABLE WATER MUST BE SIZED
AND INSTALLED WITHIN THIS PIPING SYSTEM BETWEEN THE CHECK VALVE AND THE COLD WATER INLET OF THE SOLAR WATER HEATER.
4. AN ANTI-SCALD MIXING VALVE IS RECOMMENDED IF THE DOMESTIC HOT WATER SETTING IS ABOVE 120F.
5. A MINIMUM OF 12 DIAMETERS OF STRAIGHT PIPE MUST BE INSTALLED UPSTREAM OF ALL CIRCULATORS.
6. MAKE SURE TANK IS FULLY PURGED OF AIR BEFORE POWER IS TURNED ON TO THE BACKUP HEAT SOURCE.
7. CIRCULATORS SHOWN IN THE HYDRONIC BOILER PIPING ABOVE SHOULD HAVE AN INTEGRAL FLOW CHECK OR ALTERNATELY USE A STOCK PUMP WITH AN EXTERNAL
SPRING TYPE CHECK VALVE.
LP-179-R
REV. 10/5/07
Fig. 3-2
PHOENIX SOLAR PIPING WITH AIR HANDLER
Summary of Contents for Phoenix
Page 1: ... Installation Operation Maintenance 2007 Heat Transfer Products Inc ...
Page 31: ...30 WIRING F INTERNAL WIRING PART 6 START UP PROCEDURE CONTINUED Phoenix Connector Diagram ...
Page 41: ...40 MAINTENANCE NOTES ...
Page 42: ...41 MAINTENANCE NOTES ...
Page 43: ...42 MAINTENANCE NOTES ...
Page 44: ... 2008 2007 Heat Transfer Products Inc www htproducts com LP 179 REV 4 5 08 ...
Page 68: ...23 ...
Page 69: ...24 ...
Page 73: ...28 MAINTENANCE NOTES ...
Page 74: ...29 MAINTENANCE NOTES ...
Page 75: ...30 MAINTENANCE NOTES ...