The Heat-N-Glo fireplace models discussed in this

Installers

Guide

 have been tested to certification standards and listed

by the applicable laboratories.

  CERTIFICATION STANDARD

  MODEL

 SL-550TV-C, SL-750TV-C, SL-950TV-C

  LABORATORY

Underwriters Laboratories

  TYPE

B-Vent Decorative

  STANDARD

 ANSIZ21.50•CGA2.2

Installation Codes

The fireplace installation must conform to local codes. Before
installing the fireplace, consult the local building code agency
to ensure that you are in compliance with all applicable
codes, including permits and inspections. In the absence of
local codes, the fireplace installation must conform to the
National Fuel Gas Code ANSI Z223.1 (in the United States)
or the CAN/CGA-B149 Installation Codes (in Canada). The
appliance must be electrically grounded in accordance with
local codes or, in the absence of local codes with the National
Electric Code ANSI/NFPA No. 70 (in the United States), or
to the CSA C22.1 Canadian Electric Code (in Canada).

This model (natural gas and propane) can be installed in a
bedroom (in the United States) which has a total volume of
unconfined space appropriate to the particular installation.
Refer to the National Fuel Gas Code ANSI Z223.1/NFPA54
(current edition). The Uniform Mechanical Code - (current
edition), and local Building Officials for the options allowed
in obtaining an effective bedroom volume of unconfined space.
This model (natural gas and propane) can be installed in a
bedroom (in Canada) if a thermostat (Model WH-STAT) is
installed with the unit. Consult local code authorities.  Detailed
installation instructions for Model WH-STAT are included with
the kit.

Approvals and Codes

Approvals Listing and Codes

Les modèles de foyer Heat-N-Glo dont il est question dans
ce

Guide d’installation

 ont été testés conformément aux

normes d’homologation et ont été approuvés par les
laboratoires compétents.

  NORME D’HOMOLOGATION

  MODÈLES

SL-550TV-C, SL-750TV-C, SL-950TV-C

  LABORATOIRE

Underwriters Laboratories

  TYPE

Foyer décoratif à système
d’évacuation de type B

  NORMES

ANSIZ21.50•CGA2.2

Codes d’installation

L’installation du foyer doit être conforme aux codes locaux.
Avant d’installer le foyer, consultez les autorités locales en
matière de codes de construction afin de vous assurer que
vous respectez tous les codes en vigueur, y compris les
permis de construire et les inspections. En l’absence de
codes locaux, l’installation du foyer doit être conforme au
code américain

National Fuel Gas Code

 ANSI Z223.1 (aux

États-Unis) ou aux Codes des installations CAN/CGA-B149
(au Canada). L’appareil doit être muni d’un fil de terre
conformément aux codes locaux ou, en l’absence de codes
locaux, au code américain

National Electric Code

 ANSI/

NFPA n°70 (aux États-Unis) ou au Code électrique canadien
CSA C22.1 (au Canada).

Ce modèle (gaz naturel et propane) peut être installé dans
une chambre à coucher (aux États-Unis) ayant un volume
total d’espace libre adéquat pour l’installation en question.
Reportez-vous au code américain

National Fuel Gas Code

ANSI Z223.1/NFPA54 (édition en vigueur). Consultez 

The

Uniform Mechanical Code

 (édition en vigueur) et les autorités

locales en matière de construction pour connaître les options
autorisées afin d’obtenir un volume d’espace libre suffisant
dans une chambre à coucher. Ce modèle (gaz naturel et
propane) peut être installé dans une chambre à coucher (au
Canada) si un thermostat (modèle WH-STAT) est installé
avec l’appareil. Consultez les autorités locales. Des
instructions détaillées d’installation du modèle WH-STAT sont
incluses avec le module.

Homologations et codes

Homologations et codes

Summary of Contents for SL-550TV-C

Page 1: ...ezlapi ce leb timentoulazone Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournisseur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service...

Page 2: ...mencer l installation Si ces instructions d installation ne sont pas suivies un risque d incendie pourrait en r sulter et la garantie sera annul e Avant l allumage initial LISEZ la section du Guide de...

Page 3: ...des syst mes d vacuation d crits dans la section intitul e Installation du foyer dans le Guide d installation AUCUN AUTRE syst me ou l ment d vacuation NE PEUT TRE UTILIS Cet appareil gaz et ce syst m...

Page 4: ...es de s curit et mises en garde 2 Liste des pi ces de rechange 5 Section 1 Homologations et codes 11 Homologations et codes 11 Homologation de l appareil 11 Codes d installation 11 Installation haute...

Page 5: ...d les de foyer Heat N Glo dont il est question dans ce Guide d installation ont t test s conform ment aux normes d homologation et ont t approuv s par les laboratoires comp tents NORME D HOMOLOGATION...

Page 6: ...fice qui convient consultez le service local de distribution de gaz Si cet appareil est install une altitude sup rieure 1 370 m tres au Canada consultez les autorit s locales Homologations et codes su...

Page 7: ...tation des foyers gaz Heat N Glo Les foyers gaz syst me d vacuation de type B Heat N Glo sont con us pour expulser tous les gaz de combustion en dehors de l difice Les informations contenues dans ce G...

Page 8: ...lectrique Les d tails d encadrement et de finition Si vous d sirez installer des accessoires facultatifs dispositifs tels qu un ventilateur un interrupteur mural ou une commande distance Si le foyer d...

Page 9: ...4 402 30 3 4 780 15 3 8 390 8 1 8 206 2 1 4 55 37 3 4 960 34 1 2 878 20 1 2 526 3 1 2 90 5 127 B VENT B VENT HOOD GAS CONTROLS GAS LINE ACCESS VENT COLLARS TOP STANDOFFS ACC S DU FILAGE LECTRIQUE RATI...

Page 10: ...DE AIR ENTRETOISES SUP RIEURES COLLETS DE RACCORD DU SYST ME D VACUATION HOTTE AIR EXT RIEUR ELECTRICAL ACCESS CACHE DE LA GRILLE INF RIEURE PLAQUES SIGNAL TIQUES ET TIQUETTES COMMANDES DE GAZ ACC S D...

Page 11: ...e Sides 1 2 13 C t s Top SL 550TV C 1 1 2 38 Dessus SL 550TV C SL 750TV C 3 1 4 83 SL 750TV C SL 950TV C 3 1 4 83 SL 950TV C Ceiling 31 787 Plafond Inches mm Figure 4 Dimensionsetsp cifications de d g...

Page 12: ...carbon monoxide situation in the house tape 3 Air de compensation en cas de pression n gative dans la pi ce Avertissement en cas de pression n gative dans la pi ce En cas de pression n gative un foyer...

Page 13: ...tative Cet appareil est con u de fa on pouvoir accepter une prise d air ext rieur Gr ce l air de com pensation ext rieur la quantit d air de la pi ce utilis e pour la combustion est r duite Il est con...

Page 14: ...v s pour raccordement un conduit d vacuation de type B de 127 mm de diam tre Le mod le SL 950TV C est approuv pour raccordement un conduit d vacuation de type B de 152 mm de diam tre Un conduit d vacu...

Page 15: ...d vacuation L apparence des flammes et des braises peut varier selon le type de combustible br l et la configuration du syt me d vacuation B l ments du syst me Configuration du syst me d vacuation PRO...

Page 16: ...DE S CURIT LA FIGURE 8 ET LE TABLEAU INDIQUENT LES HAUTEURS MINIMALES RESPECTER LORSQUE LA TERMINAISON DU SYST ME D VACUATION EST LOIGN E D AU MOINS 244 CM D UN MUR VERTICAL Installing the Fireplace c...

Page 17: ...Level the fireplace from side to side and from front to back 3 Shim the fireplace with non combustible material such as sheet metal as necessary 4 Secure the fireplace to the framing by nailing or scr...

Page 18: ...mande de gaz tape 7 Conduit gaz REMARQUE Le conduit d alimentation en gaz doit tre install conform ment aux codes de construc tion locaux par un installateur qualifi approuv et ou agr selon les sp cif...

Page 19: ...ale 356 mm 356 mm d approvisionnement CE CE Pression du 89 mm 254 mm collecteur CE CE Une d rivation de visite NPT de 3 mm est pr vue sur le c t d admission et sur le c t de sortie de la commande de g...

Page 20: ...riodes prolong es De cette fa on le foyer ne pourra pas s allumer accidentellement Filage de l allumage par veilleuse Sp cifications de l appareil Le fonctionnement de cet appareil NE n cessite PAS d...

Page 21: ...TISSEMENT NE BRANCHEZ PAS DE COURANT DE 110 120 VCA L INTERRUP TEUR MURAL DE COMMANDE CELA D TRUIRAIT LAVALVE DE COMMANDE ATTENTION TIQUETEZ TOUS LES FILS AVANT DE LES D BRANCHER POUR LE SERVICE DES C...

Page 22: ...IPI Wiring Diagram RED ROUGE BLK NOIR IGNITION MODULE 3 VAC MODULE D ALLUMAGE 3V BROWN BRUN GREEN VERT ORG VALVE OPTIONAL REMOTE A DISTANCE EN OPTION REM REM FAN VENT ORG WHITE BLANC I S INTERMITTENT...

Page 23: ...on Le sch ma suivant indique le d gagement vertical minimal et les dimensions horizontales maximales correspondantes des habillages de foyer et autres saillies combustibles au dessus du bord sup rieur...

Page 24: ...SCELLAGE POUVANT R SISTER 149 C MINIMUM DOIT TRE UTILIS IL N EST PAS N CESSAIRE DE SCELLER CES JOINTS SEULS DES MAT RIAUX NON COMBUSTIBLES UTILISANT UN ADH SIF POUVANT R SISTER 149 C MINIMUM SIN CESS...

Page 25: ...installation instructions that accompany the logs or the instructions in manual bag assembly Save the log instructions with this manual If sooting occurs the logs might need to be repositioned slightl...

Page 26: ...n place des braises EMBER MATERIALS BRAISES Place dime size pieces of ember material about 1 2 inch apart near port holes in burner top Do NOT press em bers into burner ports Cover the top of the burn...

Page 27: ...ue le support soutenant la grille a t enlev reportez vous la page 31 Assurez vous que la grille repose directement sur le r fractaire V rifiez qu il n y ait pas d l ments d fectueux Tout l ment d fect...

Page 28: ...yer Bien que la fr quence de l entretien et des services de votre foyer d pende de son utilisation et du type d installation il est conseill de demander un technicien de service qualifi d inspecter l...

Page 29: ...e produit est prot g par un our plusieurs des brevets suivants tats Unis 4 112 913 4 408 594 4 422 426 4 424 792 4 520 791 4 793 322 4 852 548 4 875 464 5 000 162 5 016 609 5 076 254 5 191 877 5 218 9...

Reviews: