24
!
STARTING
COLLAR
STOVE
SEALANT
BEAD
9.5mm
25.4mm
FIRST FLUE
COMPONENT
1. Attach the First Flue Component to the
Starting Collars
To attach the first flue component to the starting collars
of the fireplace:
• Apply a 9.5 mm bead of stove cement around the
fireplace inner flue starting collar.
• Make sure that the fireplace rope gasket supplied
with the fireplace seals between the first
flue component and the outer fireplace wrap.
• Lock the flue components into place by sliding the
concentric pipe sections with four (4) equally
spaced interior beads into the fireplace collar or
previously installed component end with four (4)
equally spaced indented sections.
• When the internal beads of each outer pipe line up,
rotate the pipe section clockwise about one-quarter
(1/4) turn. The flue pipe is now locked together.
1. Apply the stove ce-
ment.
2. Line up the internal
beads and rotate the
pipe sections clock-
wise until locked.
3. Lock the flue compo-
nents into place.
4. Check the seal on the
rope gasket.
Figure 16. Attaching the First Flue Component to
the Starting Collars
WARNING:
A 9.5 MM BEAD OF STOVE CEMENT
MUST BE PLACED AROUND THE
FIREPLACE INNER FLUE STARTING
COLLAR BEFORE ATTACHING THE
FIRST FLUE COMPONENT. FAILURE
TO SEAL THIS JOINT MAY CAUSE THE
FIREPLACE TO OPERATE
IMPROPERLY. SEE THE DIAGRAM.