Flue System
Termination Kits
Flue System Components
Figure 4. Flue Components and Terminations
A. Flue System Approvals
These models have flue starting collars on both the top
and the back of the unit. Depending upon the
installation, decide which ONE set of starting collars
will be used to attached the flue system. The starting
collar sealing cap must remain on the starting collar
NOT used.
These models use SL-D-series, direct flue components
when using the
TOP
flue collars and D-series direct flue
components when using the
REAR
flue collars.
WARNING: YOU MUST NOT MIX D-SERIES
AND SL D-SERIES COMPONENTS IN ANY
FLUE SYSTEM CONFIGURATION.
Approved flue system components are labeled for
identification.
NO OTHER FLUEING SYSTEMS OR
COMPONENTS MAY BE USED
. Detailed installation
instructions are included with each flue termination kit
and should be used in conjunction with this
Installers
Guide
. Figure 4 shows flue system components and
terminations.
Identifying Flue Components
The flue systems installed on this gas fireplace may
include one, two, or three 90°
elbow assemblies. The
relationships of vertical rise to horizontal run in flue
configurations using 90° elbows
MUST BE
strictly
adhered to. The rise to run relationships are shown in the
flueing drawings and tables on the next several pages.
NOTE:
Two 45° elbows may be used in place of one
90° elbow. You
MUST
always maintain the
MAXIMUM
and
MINIMUM
rise-to-run ratios in the flue system
when using 45° elbows.
Step 3
Installing the
Flue System
!
SL D-SERIES
D-SERIES
DVK-01D
DVK-TVCD
DVK-01TRD
SLK-01D
SLK-991DA
SLK-01TRD