16
Step 9. Before Lighting the Appliance
Before
lighting the appliance, be sure to do the following:
Remove all paperwork from underneath the fireplace.
Review safety warnings and cautions
• Read the
Safety and Warning Information
section at
the beginning of this
Installers Guide
.
Double-check for gas leaks
• Before lighting the appliance, double-check the unit for
possible gas leaks.
Double-check vent terminations for obstructions.
• Before lighting the appliance, double-check the unit for
possible obstructions that could be blocking the vent ter-
minations.
Double-check for faulty components
• Any component that is found to be faulty
MUST BE
re-
placed with an approved component. Tampering with the
appliance components is
DANGEROUS
and voids all war-
ranties.
A small amount of air will be in the gas supply lines. When
first lighting the appliance, it will take a few minutes for the
lines to purge themselves of this air. Once the purging is
complete, the appliance will light and will operate normally.
Subsequent lightings of the fireplace will not require this
purging of air from the gas supply lines,
unless
the gas
valve has been turned to the OFF position
, in which
case the air would have to be purged.
NOTE:
The fireplace should be run 3 to 4 hours on the initial
start-up. Turn it off and let it cool completely. Remove and
clean the glass. Replace the glass and run the fireplace for
an additional 8 hours. This will help to cure the chemicals
used in the paint and logs.
Step 10. Lighting the Appliance
You’ve reviewed all safety warnings, you’ve checked the
appliance for gas leaks, you know the vent system is
unobstructed, and you’ve checked for faulty components.
Now you’re ready to light the appliance.
WARNING: PLEASE REFER TO THE USER’S
MANUAL FOR ALL CAUTIONS, SAFETY, AND
WARNING INFORMATION PERTAINING TO THE
LIGHTING AND OPERATION OF THE APPLIANCE.
After the Installation
LEAVE THIS INSTALLATION MANUAL WITH
THE APPLIANCE FOR FUTURE REFERENCE.
!
!
3. Reconnect the low voltage wires to the ON/OFF switch.
4. Attach surround by lifting slightly above front fireplace
opening, such that surround hangs on top of the front
frame of the unit. The bottom should swing into place
such that studs (lower corners of unit) protrude through
slotted holes.
5. Secure in place with provided wing nuts.
NOTE: PLACE THE THREE INSULATION PIECES INTO
THE CAVITIES AT THE BACK OF THE SURROUND BE-
FORE POSITIONING THE INSERT INTO THE FACTORY-
BUILT OR MASONRY FIREPLACE. THIS INSULATION
WILL HELP SEAL FOR COLD AIR LEAKS.
Figure 12
Figure 12 shows the minimum vertical and corresponding
maximum horizontal dimensions of mantels or other com-
bustible projections above the gas fireplace.
MANTEL
TOP OF UNIT
12” MIN.
12” MAX.