Heat-Flo 115-D Installation, Operating And Servicing Instructions Download Page 30

Heat-­‐Flo,   Inc.|   Solar   Hot   Water   Storage   Tanks   

Page|   26   

4.

Water Quality: The warranties extended by HFI are conditioned upon potable water with a Ph 
not

 

to exceed 8.0 and not below 6.0. and  / or chloride concentrations not to exceed 

10

0 parts per

 

million (ppm). HFI specifically disclaims liability of any kind resulting from or relating to

 

potable water that does not match these characteristics.

5.

Your home contains any type of water softening system, that the system is installed and

 

maintained in accordance with the manufacturer’s specifications.

6.

Any failure or malfunction does result from improper or negligent operation, accident, abuse
(including freezing), misuse, unauthorized alteration or improper repair or maintenance.

7.

Any failure or malfunction does not result from failure to keep the unit full of potable water, free

 

to circulate at all times; and the tank free of damaging water sediment or scale deposits.

8.

The unit is used within the United States, its territories or possessions, or Canada.

9.

The warranty does not cover labor costs, shipping charges, or deliver expenses, nor administrative

 

fees incurred by the purchaser in removing or reinstalling the unit. Heat-Flo will not accept

 

claims 

for labor costs incurred by the original consumer purchaser in removing or reinstalling the

 

water 

heater.

10.

Malfunctions resulting from, or repairs necessitated by, uses of the water heater for purposes

 

other than that for which it was designed, or resulting from flood, fire, wind, or lightning. 

OWNER’S RESPONSIBILITIES 

The owner or installer must: 
1.

Have the storage tank installed with a vacuum relief valve and a temperature and pressure relief valve in accordance with local, state, and
federal codes and ordinances bearing the listing marks of the American Society of Mechanical Engineers (A.S.M.E). 

2.

Operate the storage assembly at a pressure below that shown on the rating plate on the pressure relief valve. 

3.

Keep the tank free of scale deposits. 

4.

Make provisions so if the tank or any component part or connection should leak, the resulting flow of water will not cause damage
to the area in which it is installed.

The warranty hereunder does not apply to defects resulting from:

1.

Freezing, excessive pressure, or leaks at water connections.

2.

Failure of a component, control or component part other than a component part manufactured solely by HFI.

3.

Any cause similar to the above, not resulting solely due to defective material and/or workmanship. 

4.

Water Quality: The warranties extended by HFI are conditioned upon potable water with a Ph not to exceed 8.0 and not below 6.0, and/ or
chloride concentrations not to exceed 100 parts per million (ppm). HFI specifically disclaims liability of any kind resulting from or relating
to potable water that does not match these characteristics.

LIMITATION OF WARRANTIES AND REMEDIES 

THE  FOREGOING  WARRANTIES  ARE  EXCLUSIVE  AND  ARE  GIVEN  AND  ACCEPTED  IN  LIEU  OF  ANY  AND  ALL  OTHER 
WARRANTIES,  EXPRESS  OR  IMPLIED,  INCLUDING  WITHOUT  LIMITATION  THE  IMPLIED  WARRANTIES  OF 
MERCHANTABILITY  AND  FITNESS  FOR  PARTICULAR  PURPOSE,  AND  ANY  OBLIGATION,  LIABILITY,  RIGHT,  CLAIM,  OR 
REMEDY  IN  CONTRACT  OR  TORT,  WHETHER  OR  NOT  ARISING  FROM  HEAT-FLO,  INC.’S  NEGLIGENCE,  ACTUAL  OR 
IMPUTED. 
THE  REMEDIES  OF  THE  ORIGINAL  CONSUMER  PURCHASES  SHALL  BE  LIMITED  TO  THOSE  PROVIDED  HEREIN  TO  THE 
EXCLUSION  OF  ANY  OTHER  REMEDIES  INCLUDING  WITHOUT  LIMITATION,  INCIDENTAL  OR  CONSEQUENTIAL  DAMAGES 
INCLUDING, BUT NOT LIMITED TO, PROPERTY DAMAGE, LOST PROFIT, OR DAMAGES ALLEGED TO HAVE BEEN CAUSED 
BY ANY FAILURE OF HEAT-FLO, INC. TO MEET ANY OBLIGATION UNDER THIS AGREEMENT INCLUDING THE OBLIGATION 
TO REPAIR AND REPLACE SET FORTH ABOVE. 
NO  AGREEMENT  VARYING  OR  EXTENDING  THE  FOREGOING  WARRANTIES,  REMEDIES,  OR  THIS  LIMITATION  WILL  BE 
BINDING UPON HEAT-FLO, INC. UNLESS IN WRITING AND SIGNED BY A DULY AUTHORIZED OFFICER OF HEAT-FLO, INC. 
THE WARRANTY STATED HEREIN IS NOT TRANSFERABLE AND SHALL BE FOR THE BENEFIT OF THE ORIGINAL CONSUMER 
PURCHASER OF A WATER HEATER ONLY. 
These warranties give you specific legal rights, and you may also have other rights which vary from state to state.  Some states do not allow the 
exclusion or limitation of incidental or consequential damages so this limitation or exclusion may not apply to you. 

These are the only written warranties applicable to water heaters manufactured and sold by Heat-Flo, Inc. Heat-Flo, Inc. neither assumes nor 

authorizes anyone to assume for it any other obligation or liability in connnection with said water heaters.

SERVICE REQUESTS 

FOR SERVICE UNDER THESE WARRANTIES CONTACT HEAT-FLO, INC., AT THIS ADDRESS: 

Heat-Flo, Inc., P.O. Box 612, Uxbridge, MA 01569 

At the time a claim is filed the original consumer purchaser must present a copy of the original sales receipt, and a deed, utility bill, or equivalent 
document evidencing both ownership of the water heater and installation in the dwelling or commercial property owned by the original consumer 
purchaser.    With  regard  to  claims  made  by  original  consumer  purchasers  of  water  heaters  used  in  commercial  settings  as  that  term  is  defined 
herein, in no event shall notification of a service  request be received later than five years from the date of purchase. 

he obligations under this warranty apply only to domestic hot water tank installations where the warranty registration card has been completed by 
the owner of the site of the original installation and received by Heat-Flo in accordance with the terms and conditions herein set out and Heat-Flo 
has  been  notified  of  the  alleged  defect  or  deficiency  within  forty  eight  (48)  hours  from  the  occurrence  or  discovery  of  the  alleged  defect  or 
deficiency. 
Heat-Flo, Inc. reserves the right to change specifications or discontinue models without notice.           Bulletin WAR-SOLAR-040115  Page 2 of 2 

Summary of Contents for 115-D

Page 1: ...ovided to assist in enabling the installation operation and maintenance of this water heater For your comfort safety and convenience we recommend that this water heater be installed and serviced by a...

Page 2: ......

Page 3: ...evere personal injury death or substantial property damage if ignored Indicates the presence of a hazard which can cause severe personal injury death or substantial property damage if ignored Indicate...

Page 4: ...Installation Considerations 3 Dimensions and Capacities 4 Piping 10 13 Electrical 14 16 18 Operation 14 Important Scalding Information 14 15 Maintenance 19 21 Troubleshooting 22 Boiler Supply Ratings...

Page 5: ...temperature relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements for Relie...

Page 6: ...ater NEVER leave a child or disabled person unattended in a bathtub or a shower IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER WARNING When using electrical applian...

Page 7: ...hot tubs and the use of more than one shower at a time Increase the tank size if these factors are present Consult ASHRAE sizing guides and other references Dimensions weights ratings and capacities...

Page 8: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 4 Heat Exchanger Coil Output TABLE 1 TABLE 2...

Page 9: ...for each zone and the water heater is controlled with an additional zone valve Select a valve with a low pressure drop and assure minimum flow with adequate pipe sizing PRIORITY OR NON PRIORITY FOR H...

Page 10: ...e are Bottom 0 Left Right and Rear Sides 3 Front 30 Top 6 ADDITIONAL RECOMMENDED COMPONENTS 1 Shut Off Valves Allows the isolation of the water heater from the boiler system during service 2 Unions Al...

Page 11: ...ppm Heat Flo s standard warranty does not cover problems caused by improper water Ph or excessive levels of chlorides Damage to tanks caused by improper water quality is not covered under the warrant...

Page 12: ...and the discharge line The discharge opening must not be subjected to blockage or freezing DO NOT thread plug or cap the discharge line It is recommended that a minimum clearance of four 4 inches be...

Page 13: ...The use of a check valve is required to prevent back flow through the water heater during operation of the space heating system ZONE VALVE SYSTEM For a space heating system that uses Zone Valves refer...

Page 14: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 10 Indirect Piping...

Page 15: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 11 Indirect Piping...

Page 16: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 12 Solar Piping...

Page 17: ...The location of the tapping will not allow for the mixing of back up heated hot water boiler indirect of electric element into the lower solar heated section of the tank When an anti scald device is i...

Page 18: ...e tank has reached the temperature setting the tank thermostat opens and de energizes the circulator and the boiler If there is a call for space heating the boiler will continue to run until the room...

Page 19: ...hrough the cycle of heating cold water and satisfying at the new lower temperature Additional temperature checks should follow the completion of a heating cycle Further adjustments may be required aft...

Page 20: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 16 Indirect Wiring...

Page 21: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 17 Indirect Wiring...

Page 22: ...tion point for connecting a ground wire All wiring shall be done in accordance with all applicable local and state codes Adjusting the Temperature Dial on the Thermostat The minimum potable water temp...

Page 23: ...kage at the joints unions and shut off valves Repair as required 2 Temperature and Pressure Relief Valve Annual The temperature and pressure relief valve should be checked to ensure that it is in oper...

Page 24: ...il and the thermostat 6 Using a funnel pour one gallon of commercial ice maker cleaning solution into the tank through the relief valve opening Follow the instructions cautions and warnings supplied w...

Page 25: ...temperature control can be turned to the side to allow easier access 4 After the water heater has drained and cooled remove the anode using a 1 6 point socket and a breaker bar 5 Inspect the anode an...

Page 26: ...ale See chemical cleaning instructions Pg 16 Clean or replace filter Insufficient runs out of hot water at the faucet Thermostat setting too low Undersized boiler with no priority to domestic water he...

Page 27: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 23 180 F Boiler Supply IBR Rating Condition HIGH OUTPUT UNITS 60 HO 80 HO 115 HO EXTRA HIGH OUTPUT UNITS 85 XHO 115 XHO...

Page 28: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 24 Replacement Parts List...

Page 29: ...ne of two time periods 1 LIMITED FIVE YEAR WARRANTY for five years as long as the original consumer purchaser owns the home residence in which the water heater is located 2 ADDITIONAL LIMITED WARRANTY...

Page 30: ...characteristics LIMITATION OF WARRANTIES AND REMEDIES THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LI...

Page 31: ......

Page 32: ...Heat Flo Inc 15 Megan Ct P O Box 612 Uxbridge MA 01569 USA Phone 508 278 2400 Fax 508 278 2466 e mail sales heat flo com www heat flo com Providing Solutions through Superior Design...

Reviews: