Heat-Flo 115-D Installation, Operating And Servicing Instructions Download Page 15

Heat-­‐Flo,   Inc.|   Solar   Hot   Water   Storage   Tanks   

   

Page|   11   

   

Indirect   Piping

   

   

Summary of Contents for 115-D

Page 1: ...ovided to assist in enabling the installation operation and maintenance of this water heater For your comfort safety and convenience we recommend that this water heater be installed and serviced by a...

Page 2: ......

Page 3: ...evere personal injury death or substantial property damage if ignored Indicates the presence of a hazard which can cause severe personal injury death or substantial property damage if ignored Indicate...

Page 4: ...Installation Considerations 3 Dimensions and Capacities 4 Piping 10 13 Electrical 14 16 18 Operation 14 Important Scalding Information 14 15 Maintenance 19 21 Troubleshooting 22 Boiler Supply Ratings...

Page 5: ...temperature relief valve certified by a nationally recognized testing laboratory that maintains periodic inspection of production of listed equipment or materials as meeting the requirements for Relie...

Page 6: ...ater NEVER leave a child or disabled person unattended in a bathtub or a shower IMPORTANT SAFETY INSTRUCTIONS READ ALL INSTRUCTIONS BEFORE USING THIS WATER HEATER WARNING When using electrical applian...

Page 7: ...hot tubs and the use of more than one shower at a time Increase the tank size if these factors are present Consult ASHRAE sizing guides and other references Dimensions weights ratings and capacities...

Page 8: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 4 Heat Exchanger Coil Output TABLE 1 TABLE 2...

Page 9: ...for each zone and the water heater is controlled with an additional zone valve Select a valve with a low pressure drop and assure minimum flow with adequate pipe sizing PRIORITY OR NON PRIORITY FOR H...

Page 10: ...e are Bottom 0 Left Right and Rear Sides 3 Front 30 Top 6 ADDITIONAL RECOMMENDED COMPONENTS 1 Shut Off Valves Allows the isolation of the water heater from the boiler system during service 2 Unions Al...

Page 11: ...ppm Heat Flo s standard warranty does not cover problems caused by improper water Ph or excessive levels of chlorides Damage to tanks caused by improper water quality is not covered under the warrant...

Page 12: ...and the discharge line The discharge opening must not be subjected to blockage or freezing DO NOT thread plug or cap the discharge line It is recommended that a minimum clearance of four 4 inches be...

Page 13: ...The use of a check valve is required to prevent back flow through the water heater during operation of the space heating system ZONE VALVE SYSTEM For a space heating system that uses Zone Valves refer...

Page 14: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 10 Indirect Piping...

Page 15: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 11 Indirect Piping...

Page 16: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 12 Solar Piping...

Page 17: ...The location of the tapping will not allow for the mixing of back up heated hot water boiler indirect of electric element into the lower solar heated section of the tank When an anti scald device is i...

Page 18: ...e tank has reached the temperature setting the tank thermostat opens and de energizes the circulator and the boiler If there is a call for space heating the boiler will continue to run until the room...

Page 19: ...hrough the cycle of heating cold water and satisfying at the new lower temperature Additional temperature checks should follow the completion of a heating cycle Further adjustments may be required aft...

Page 20: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 16 Indirect Wiring...

Page 21: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 17 Indirect Wiring...

Page 22: ...tion point for connecting a ground wire All wiring shall be done in accordance with all applicable local and state codes Adjusting the Temperature Dial on the Thermostat The minimum potable water temp...

Page 23: ...kage at the joints unions and shut off valves Repair as required 2 Temperature and Pressure Relief Valve Annual The temperature and pressure relief valve should be checked to ensure that it is in oper...

Page 24: ...il and the thermostat 6 Using a funnel pour one gallon of commercial ice maker cleaning solution into the tank through the relief valve opening Follow the instructions cautions and warnings supplied w...

Page 25: ...temperature control can be turned to the side to allow easier access 4 After the water heater has drained and cooled remove the anode using a 1 6 point socket and a breaker bar 5 Inspect the anode an...

Page 26: ...ale See chemical cleaning instructions Pg 16 Clean or replace filter Insufficient runs out of hot water at the faucet Thermostat setting too low Undersized boiler with no priority to domestic water he...

Page 27: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 23 180 F Boiler Supply IBR Rating Condition HIGH OUTPUT UNITS 60 HO 80 HO 115 HO EXTRA HIGH OUTPUT UNITS 85 XHO 115 XHO...

Page 28: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 24 Replacement Parts List...

Page 29: ...ne of two time periods 1 LIMITED FIVE YEAR WARRANTY for five years as long as the original consumer purchaser owns the home residence in which the water heater is located 2 ADDITIONAL LIMITED WARRANTY...

Page 30: ...characteristics LIMITATION OF WARRANTIES AND REMEDIES THE FOREGOING WARRANTIES ARE EXCLUSIVE AND ARE GIVEN AND ACCEPTED IN LIEU OF ANY AND ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING WITHOUT LI...

Page 31: ......

Page 32: ...Heat Flo Inc 15 Megan Ct P O Box 612 Uxbridge MA 01569 USA Phone 508 278 2400 Fax 508 278 2466 e mail sales heat flo com www heat flo com Providing Solutions through Superior Design...

Reviews: