Heat-‐Flo, Inc.| Solar Hot Water Storage Tanks
Page| 21
outlined on page 6. Failure to inspect the anode regularly and replace if necessary could
result in damage to the water heater. If this unit is installed and maintained according to
the instructions and conditions in this manual, this product will last for a long time.
1. Close domestic water isolation valves.
2. Drain the water heater completely and allow it to cool off.
3. Remove the anode cover on the front of the unit. See figures on pages 2 and 3. The
temperature control can be turned to the side to allow easier access.
4. After the water heater has drained and cooled, remove the anode using a 1 ¾” 6-‐point
socket and a breaker bar.
5. Inspect the anode and replace if needed. The anode should be replaced when more
than 6” of core wire is exposed. The anode should be replaced with a Heat-‐Flo supplied
anode only. See above. The brass hex on the anode is 1 ¼ NPT and installs into a 1 ¼
stainless half coupling on the shell of the tank. This part will need to be properly Teflon
taped and coated with a quality Teflon based pipe sealant.
6. Replace the inspection cover.
7. Refill the water heater, and restore to operation.
8. Verify operation of boiler and water heater.
Summary of Contents for 115-D
Page 2: ......
Page 8: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 4 Heat Exchanger Coil Output TABLE 1 TABLE 2...
Page 14: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 10 Indirect Piping...
Page 15: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 11 Indirect Piping...
Page 16: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 12 Solar Piping...
Page 20: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 16 Indirect Wiring...
Page 21: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 17 Indirect Wiring...
Page 28: ...Heat Flo Inc Solar Hot Water Storage Tanks Page 24 Replacement Parts List...
Page 31: ......