Listing and Code Approvals 

A. Appliance Certification

This stove has been tested and listed in accordance with 

UL 2021

 Standards for fixed and location-dedicated electric 

room heaters in the United States, the current 

CSA C22.2 

NO. 46

 in Canada, and has been listed by Underwriters’ 

Laboratoreis Inc. for installation as described in this manual. 
All components are UL or CSA safety certified.

If you need assistance during isntallation, please contact 
your local dealer or the Heat & Glo Technical Services De-
partment, Hearth & Home Technologies Inc., 800 West Jef-
ferson, Lake City, MN 55041, 1-888-427-3973.

Hearth & Home Technologies disclaims any 
responsibility for, and the warranty will be 
voided by, the following actions:

•  Installation and use of any damaged appliance.
• Modification of the appliance.
• 

Installation other than as instructed by Hearth & Home 
Technologies.

•  Installation and/or use of any component part not 

approved by Hearth & Home Technologies.

WARNING

Fire Risk
Shock Risk

Model #

Description

Voltage

Watts Amps

TiaraE

Electric 

Stove

120

1500

12.5

Summary of Contents for TiaraE

Page 1: ...e for use and operation Read understand and follow these instructions for safe installation and operation HOT DO NOT TOUCH SEVERE BURNS MAY RESULT CLOTHING IGNITION MAY RESULT WARNING Keep children aw...

Page 2: ...ments and product manuals Your new Heat Glo electric stove will give you years of durable use and trouble free enjoyment Welcome to the Heat Glo family of electric products Homeowner Reference Informa...

Page 3: ...ove Set Up A Leg Leveling System 7 5 Operating Instructions A Main Power Switch 8 B Intensity Switch 8 C Heater Switch 8 D Thermostat 8 6 Troubleshooting 7 Maintenance and Servicing the Fireplace A Cl...

Page 4: ...assistance during isntallation please contact your local dealer or the Heat Glo Technical Services De partment Hearth Home Technologies Inc 800 West Jef ferson Lake City MN 55041 1 888 427 3973 Hearth...

Page 5: ...nd cause a risk of fire However if you have to use an extension cord the cord shall be No 16 AWG minimum size and rated not less than 1875 watts Always use properly grounded fused and polarized outlet...

Page 6: ...ing papers clothes and curtains at least 3 ft 9 m from the front of the appliance WARNING Electrocution Risk NEVER locate this stove where it may fall into a bathtub or other water container DANGER 2...

Page 7: ...legs with the nuts on the bottom Use a 5 32 in 3 96 mm Allen wrench to adjust legs to the desired level See Figure 4 2 Figure 4 1 Leveling Legs Components Figure 4 2 Assembled Leveling Legs Note Two a...

Page 8: ...witch Controls the intensity of the ember bed and flame C Heater Switch The heater switch provides power to the heater system The RC ELEC HNG remote control does not control this function D Thermostat...

Page 9: ...ome on A Heating system switch is OFF Turn the heating system switch to the ON position B Thermostat is set too low Turn the thermostat knob clockwise until you hear a click C Heating system is overhe...

Page 10: ...lect dust particles These can be removed by buffing lightly with a clean dry cloth To remove fingerprints or other marks the glass can be cleaned with a damp cloth using a good quality household glass...

Page 11: ...ight bulbs Light bulb access is on the bottom front of the stove Locate and remove the three screws See Figures 7 2 and 7 3 Lower the cover plate to access the light bulbs Carefully remove the burned...

Page 12: ...4035 822 Rev F 01 05 12 8 Reference Materials A TiaraE Dimensions 18 1 2 in 470 mm 18 1 2 in 470 mm 27 in 686 mm 35 1 2 in 902 mm with optional decorative shelves 23 1 2 in 591 mm without optional dec...

Page 13: ...replaced it must be replaced with an equivalent wire gauge and 105 degree rated wire M FAN THERMOSTAT HEATER SWITCH BLK BLK MAIN POWER M BLK BLK WHT L WHT ORG WHT BLK BLK BLK BLK DIMMER SWITCH L BLK W...

Page 14: ...Heat Glo TiaraE 4035 822 Rev F 01 05 16 D Optional Components RC ELECT HNG Remote Control...

Page 15: ...pany damage or failure has resulted from accident alteration misuse abuse incorrect installation or operation on an incorrect power source The foregoing is in lieu of all other warranties expressed im...

Page 16: ...follow these instructions for safe installation and operation This product may be covered by one or more of the following patents United States 4593510 4686807 4766876 4793322 4811534 5000162 5016609...

Reviews: