17
Heat & Glo • SL-550TRSI-AUE • 2079-902 Rev. K • 10/08
!
WARNING: FAILURE TO REMOVE IN-
SULATION IN THE SET OF COLLARS
YOU ARE USING COULD CAUSE A
FIRE.
Appliance Preparation
After determining which set of starting collars will
be used (top or rear), follow flueing instructions
accordingly.
WARNING: FIRE RISK ONCE APPLI-
ANCE IS SETUP FOR TOP OR REAR
FLUEING, IT CANNOT BE CHANGED
AT A LATER TIME. IF FLUE CAP
AND COMPONENTS PREVIOUSLY
REMOVED ARE IMPROPERLY REIN-
STALLED, A FIRE MAY RESULT.
!
CAUTION
2 SCREWS
Top Flue
Figure 18.
Rotate the top heat shield to the vertical
position as shown above. The heat shield must remain
in the vertical position.
Figure 20.
Remove the fl ue cap.
Figure 21.
Remove the insulation basket and white
insulation from the center fl ue pipe.
Figure 17
. For top fl ue, remove the two screws hold-
ing the top heat shield in place. For rear fl ue, see
next page.
Figure 19.
Replace the two screws as shown.
Sharp edges-Wear protective gloves and safety glasses
during installation.
WARNING: YOU MUST LEAVE THE
INSULATION AND FLUE CAP IN
PLACE IN THE SET OF COLLARS
YOU ARE NOT USING.
!
WARNING: FIRE RISK DO NOT RE-
MOVE HEAT SHIELD. ELEVATED
HEADER TEMPERATURES MAY
CAUSE A FIRE.
!
2 SCREWS