Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 R14 • 11/14
41
RED JUMPER
WIRE TO
BROWN
W
H
IT
E
ORANGE
INTERMITTENT
PILOT IGNITOR
IGNITION MODULE
3 VAC
REMOTE RECEIVER
O
R
A
N
G
E
G
R
EE
N
BLA
CK
RED
VALVE
GROUND TO
FIREPLACE CHASSIS
TRANSFORMER
3 VAC
PLUG
IN
O
R
A
N
G
E
O
R
A
N
G
E
R
ED
R
ED
FLAME
CONTROL
SOLENOID
BATTERY PACK
I
S
RED
RED
ORANGE
ORANGE
B
R
N
O
R
A
N
G
E
O
R
A
N
G
E
B
R
N
PIGGYBACK
ON/OFF SWITCH
R
ED
R
ED
B
R
N
REMOTE
RECEIVER
Figure 8.31 Remote Control IPI Wiring Diagram
Wiring the flame control solenoid:
Connect the two leads from the flame control solenoid to the
orange leads from the receiver. See Figure 8.31.
Install a manometer into the pressure tap. Plug the remote
receiver into the 110-120 VAC power supply.
Light the appliance as directed in Section 9 of this manual.
Set the manifold pressure on the gas valve by rotating
the flame control solenoid. Adjust until the reading on the
manometer is 3.5 in. W.C. for natural gas or 10 in. W.C. for
LP.
Tighten the jam nut to the face of the variable regulator
body. See Figure 8.30. Turn the main gas knob on the gas
valve OFF. Remove the manometer from the pressure tap
and screw the tap closed.
Follow the instructions from the remote control kit to operate
and program the remote control.