Heat & Glo • PALOMA-BZ-MOD, PALOMA-GR-MOD, PALOMA-GY-MOD • 2189-900 R14 • 11/14
28
C. IntelliFire
®
Ignition System Wiring
This appliance requires a 110-120 VAC supply to the
appliance junction box for operation. A wiring diagram is
shown in
Figure 7.2
on the next page.
This appliance is equipped with an IntelliFire
®
control valve
which operates on a 3 volt system.
This appliance is supplied with a 3 volt AC transformer,
which requires the installation of the supplied junction box.
This appliance is supplied with a battery pack that requires
two D cell batteries (not included). Batteries cannot be placed
in the battery pack while using the 3 volt AC transformer.
Conversely, the transformer must be unplugged if the
battery pack is used.
NOTICE:
Battery polarity must be correct or module damage
will occur.
1.
This appliance may be used with a wall switch, wall
mounted thermostat and / or a remote control
2.
If using thermostat, use one compatible with a millivolt
gas valve system.
3.
Follow parameters for locating thermostat (see individual
thermostat instructions) to ensure proper operation of
appliance.
4. Use low resistance thermostat wire for wiring from
ignition system to the wall switch and thermostat.
5. Use the following chart for wire sizing.
6.
Keep wire lengths as short as possible by removing any
excess wire length.
7.
Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
8.
Ensure the thermostat is mounted level for accurate
readings.
9. The thermostat should be mounted on an inside wall and
not in direct line with the appliance convection air.
10.
If the thermostat is located too close to the appliance,
you may need to set the temperature setting slightly
higher to maintain the desired temperature in your
home.
Do not connect this appliance to a thermostat serving
any other appliance.
Bedroom installation in Canada requires this appliance
to be connected to a thermostat.
Wire Size
Max. Length
16 gauge
65 feet
18 gauge
40 feet
20 gauge
25 feet
22 gauge
18 feet
A. Recommendation for Wire
See Figure 7.1 for recommended maximum lead length (two
wire) when using wall thermostat/switch
.
7
Electrical Information
NOTE:
This appliance must be electrically wired and grounded
in accordance with local codes or, in the absence of local codes,
with
National Electric Code ANSI/NFPA 70-latest edition
or
the
Canadian Electric Code, CSA C221.1
.
Wire 110-120 VAC to electrical junction box.
Do NOT wire 110-120 VAC to valve.
Do NOT wire 110-120 VAC to wall switch.
• Incorrect wiring will damage millivolt valves.
• Incorrect wiring will override IPI safety lockout and
may cause explosion.
Shock hazard.
•
This appliance is equipped with a three
pronged (grounding) plug for your protection
against shock hazard and should be plugged
directly into a properly grounded three prong
receptacle. Do not cut or remove the grounding
prong from this plug.
Figure 7.1
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when it is
installed in locations such as in bathrooms or near sinks.
B. Connecting to the Appliance