Locate the machine screw underneath the firebox on the
right side. Position the temperature sensor switch/bracket
assembly over the machine screw and attach with the wing
nut. Finger tighten. See Figure 8.24.
Figure 8.25
Attach rheostat in mating feature of control shield so that
orientation of control knob is downward. See Figure 8.25.
Note:
The switch/bracket assembly must be installed so that
the sensor switch makes contact with the bottom of the firebox.
Figure 8.26
Plug the blower cord into the FAN outlet on the junction box.
Push excess wires neatly
towards the rear of the appliance.
Slide the blower into the bracket as indicated in Figure 8.27.
Ensure the blower is pushed back into the bracket to allow
the replacement of the lower access door. The magnet
strips located on the blower feet are designed to hold the
blower in place.
Plug appliance in. Turn the 110-120 VAC service "ON" at
the circuit breaker and turn the speed control switch to the
"ON" position.
Attach the ground clip to the control panel. Attach the ground
wire extension to the ground clip. Attach the blower ground
wire to the ground wire extension. Refer to Figure 8.26.
Figure 8.27
FAN BASE CONTACTS
FAN BRACKET