Place the wall thimble cover over the pipe assembly and
slide the appliance and vent assembly towards the wall,
carefully inserting the vent pipe into the vent termination
cap assembly. It is important that the vent pipe extend
into the vent termination cap a sufficient distance so as
to result in a minimum pipe overlap of 1-1/4 in. (32 mm).
Secure the connection between the vent pipe and the
vent termination cap by attaching the two sheet metal
strips extending from the vent termination cap assembly
into the outer wall of the vent pipe. Use the two sheet
metal screws provided to connect the strips to the pipe
section (
Figure 5.9
).
Figure 5.9
WALL
THIMBLE
COVER
WALL THIMBLE
VINYL SIDING STANDOFF WITH
SIDING BENEATH REMOVED
SCREWS
BOLT HORIZONTAL TOP
TO VINYL STANDOFF
SCREWS
APPLY SEALANT TO
ALL FOUR SIDES
VINYL SIDING
Figure 5.8
Note:
The attachment from the vent pipe to the vent termination
cap must be sealed with silicone. Termination caps shall not be
recessed into a wall or siding.
Fire Risk
Exhaust Fumes Risk
Impaired Performance of Appliance
• Ensure vent components are locked together
correctly.
• Pipe may separate if not properly joined.
Do NOT connect a pipe section to a termination cap without
using the telescoping flue section found on the termination
cap.
Burn Risk
• Local codes may require installation of a cap
shield to prevent anything or anyone from
touching the hot cap.
FOLD STRAP
HERE
WALL THIMBLE COVER/CEILING
FIRESTOP AS REQUIRED BY
LOCAL JURISDICTION
1/4 in. (6 mm)
STRAP
SHEET METAL
SCREW
WALL
THIMBLE
WARNING
!
WARNING
!
WARNING
!