9
Heat & Glo • 6000TRSI-AUC • 2078-900 Rev. Q • 6/10
This model is approved to use DVP-Series fl ue pipe
components. A
DVP-TRAP2
Termination Cap must be
used to terminate fl ue systems in a horizontal position.
A
DVP-TVHW
vertical Termination Cap must be used
to terminate fl ue systems in a vertical position.
Figures 1.8 through 1.15 show the flue systems
approved for these models. Approved fl ue system
components are labeled for identifi cation.
NO OTHER
FLUE SYSTEMS OR COMPONENTS MAY BE USED.
Detailed installation instructions are included with each
fl ue termination kit and should be used in conjunction
with this manual.
WARNING: THIS GAS APPLIANCE AND FLUE
ASSEMBLY MUST BE FLUED DIRECTLY TO THE
OUTSIDE AND MUST NEVER BE ATTACHED TO
A CHIMNEY SERVING A SEPARATE SOLID FUEL
BURNING APPLIANCE. EACH GAS APPLIANCE
MUST USE A SEPARATE FLUE SYSTEM-COMMON
FLUE SYSTEMS ARE PROHIBITED.
CAUTION: UNDER NO CONDITION SHOULD COM-
BUSTIBLE MATERIAL BE CLOSER THAN 3 INCHES
(2-1/2 INCHES AT WALL FIRESTOPS) FROM THE
TOP OF THE 8 INCH PIPE OR 1 INCH TO THE SIDES
AND THE BOTTOM FOR HORIZONTAL SECTIONS
OF THIS FLUE SYSTEM. VERTICAL SECTIONS OF
THIS SYSTEM REQUIRE A MINIMUM OF 1 INCH
CLEARANCE TO COMBUSTIBLE MATERIALS ALL
AROUND THE 8 INCH PIPE.
For alternative installations, other than depicted, con-
tact your dealer for further information.
Refer to Figure 1.5 for required clearances to fl ue
terminals.
MODEL FLUE TERMINATION APPROVALS
6000TRSI-AUC DVP-TRAP2, DVP-TVHW
TABLE 1
Figure 1.6
VERTICAL FLUE RESTRICTOR
If the heater installation requires a vertical fl ue ex-
ceeding 4.5 m above the unit with no horizontal fl ue
or elbows a vertical fl ue restrictor must be installed
(see Figure 1.6).
Figure 1.7
V
CAP
V
MAX. RUN
36 FT.
(10.97m)
STRAIGHT UP VERTICAL FLUE SYSTEM
Figure 1.6 shows straight up vertical fl ue system ap-
proved for use on this model.
RESTRICTOR
PLATE