Heat & Glo • 6000PLUS • 2063-900 Rev. E • 11/05
14
For Intermittent Pilot Ignition (IPI) Wiring
3 Volt Transformer
This appliance comes with a 3 volt transformer. The trans-
former plugs into the junction box, and the two leads plug
into the green control module (see Figure 8).
Appliance Requirements
This appliance requires that 110-120 VAC be wired to the
junction box included in the manual bag assembly. Maintain
correct polarity when wiring the junction box.
Figure 8. Intellifire Wiring Diagram
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING CONTROLS. WIRING ERRORS
CAN CAUSE IMPROPER AND DANGEROUS OPERA-
TION. VERIFY PROPER OPERATION AFTER SERVICING.
NEUTRAL
GROUND
REMOTE
CONTROL
HOT
LOW VOLTAGE
SEE NOTE 1
ON/OFF
WALL SWITCH
VALVE
TRANSFORMER
OUTLET
PLUG-IN
3V TRANSFORMER
FLAME SPARKER /
SENSOR
IGNITION
MODULE
(3V)
TO “R2” ON
HRV200 PLUS
BOARD
TO “R1” ON
HRV200 PLUS
BOARD
VALVE
TO “12V” ON
HRV200 PLUS BOARD
TO “H1” ON
HRV200 PLUS BOARD
ORANGE
BLUE
TEMP SENSOR
BROWN
B
R
O
W
N
PLUG-IN
TRANSFORMER
3 VAC
FAN
REM
/AU
X
TR
AN
S
H
O
T
NE
UT
R
A
L
5 4
3 2
1
5
4 3 2
1
WHITE
(SENSOR)
ORANGE
(IGNITOR)
GROUND TO
FIREPLACE
CHASSIS
I
S
IGNITOR MODULE 3 VAC
INTERMITTENT PILOT IGNITOR
OR
A
N
GE
G
R
EEN
Optional Accessories
Optional fan and remote control kits require that 110-120
VAC be wired to the fireplace junction box.
Î