HearthStone Quality Home Heating Products Inc
Tudor Model #8120
7
I
NSTALLER
’
S
I
NFORMATION
C
ODES
Adhere to all
local codes
or, in their
absence, the latest edition of THE
NATIONAL FUEL GAS CODE ANSI
Z223.1 (NFPA 54) or CAN/CGA B149
Installation Code that can be obtained from
:
AMERICAN NATIONAL STANDARDS
INSTITUTE, INC.
1430 BROADWAY
NEW YORK, NY 10018
OR
NATIONAL FIRE PROTECTION
ASSOCIATION, INC.
BATTERY MARCH PARK
QUINCY, MA 02269
A manufactured home (mobile) OEM
installation must conform with the
Manufactured Home
Construction and
Safety Standard, Title 24 CFR, Part 3280
(U.S.) or Standard for Manufactured Home
Installation, ANSI/NCBCS A225.1 or
Standard for Gas Equipped Recreational
Vehicles and mobile Housing, CSA
Z240.4.CAN/SCA Z240 MH (Canada).
(Installer l’appareil selon les codes ou
règlements locaux, ou, en l’absence de tels
règlements, selon les Codes d’installation
CAN/CGA-B149.)
I
TEMS
R
EQUIRED FOR
I
NSTALLATION
* External regulator (for propane/L.P.G. only)
* Piping which complies with local codes
* Pipe sealant approved for use with
propane/L.P.G. (resistant to sulfur compounds)
* Manual shutoff valve
* Sediment trap (see page 18)
* Tee joint
* Pipe wrench
* Phillips head screwdriver
* 7/16-inch wrench
* Other parts as required by local code
*Safety Glasses
*Gloves
P
ACKING
L
IST
1-Tudor Gas-Fired Heater
1-TEK Burner
2-Decorative TEK Firelogs
1-Tudor top casting
1-Owner’s Manual
1-Thermostat
1-40’ Thermostat wire
1-Wall thimble Insulation Blanket
1-Warranty Validation Form
Note: Vent kits and components are supplied
separately. Failure to use the venting
components specified by HearthStone
QHHP, Inc. will void your warranty and
could risk a fire.
U
NPACKING AND
I
NSPECTION
Unpack and Inspect for Damage
The Tudor is packaged by the manufacturer
to withstand shipment without damage.
However, damage can still occur during
transit; so take care to inspect for damage
when unpacking and installing the unit. If
any damage, or missing parts are detected,
immediately contact your dealer
.
Do not install, or put into service, a
damaged or incomplete heater.
The Tudor requires a pilot shield. This
shield is shipped with the unit. Make sure
the sure the shield is installed over the
pilot with the open end is to the right
(when you are facing the front of the
stove)
Inspect the Tudor for visible or concealed
damage. The unit should appear to be square
and true. The sheet metal parts should be
smooth and free of bends and dents. The
enameled cast iron should be free of chips or
cracks. If visible or concealed damage is