wall thimble
wall thimble cover (optional)
When installing
the wall pass
through you
must add the
insulation
blanket
provided.
6"straight
14" snorkel
Figure 7 Components for a typical snorkel
installation
Termination
Cap
Wall thimble
Wall thimble cover (optional)
6"straight
Wallpass
through
insulation
blanket
(REQUIRED)
Figure 8 Components for a minimum horizontal
vent configuration
I
NSTALLATION
I
NSTRUCTIONS
FOR THE
S
TANDARD
H
ORIZONTAL
T
ERMINATION
M
INIMUM
V
ENTING
K
IT
1. Install the 6” straight over the outer
collar.
2. Move the stove and pipe assembly
back until the 6” straight is flush to
the wall. Pull up on the pipe to
ensure that there is a ¼” per foot rise
coming out of the stove.
3. Draw a circle around the pipe. Use
the center of this circle as the center
point of the 10” x 10” square wall
pass through. Cut and frame the wall
pass through.
4. Place the interior wall thimble into
the 10” x 10” wall pass through.
Secure it with 4 screws (not
provided). Install the exterior portion
of the thimble in similar fashion,
overlapping the 2 sections.
5.
Place the Wall Pass through
Insulation Blanket inside of the
wall pass through as described on
page 11.
•
Caution: For building with vinyl siding,
a vinyl siding standoff should be
installed between the vent cap and the
exterior wall.
6. Install the horizontal vent
termination on the outside of the
wall. Make sure both of the retaining
straps extend through interior wall
thimble. Before attaching the vent
termination to the outside of the
house, run a bead of non-hardening
mastic around its’ outside edges, so
as to make a seal between it and the
wall.
The arrow on the end cap