Bristol DX Model 8763
27
Figure 28
– Pilot in LP (LP text visible to rear
of Pilot Tower)
Figure 29
– Pilot in LP (slide gate to rear of
Pilot Tower)
Initial Adjustments
Once the Bristol is set in place, connected and
assembled as described in the Clearances To
Combustibles,
Venting
Components
&
Configurations,
Electrical
Connections,
Log
Placement and Maxitrol GV60 Control System
Features & Gas Supply Connections sections of this
manual, the unit is ready to be lit and adjusted to its
particular installation. Hearthstone tests each unit
prior to shipment, so ignition should take place
without issue. However,
a number
of small
adjustments may be necessary to compensate for
variations in gas pressure, altitude, and other factors
particular to each installation. Read pages 29-30 to
complete installation specific setup.
TO SHUT DOWN THE APPLIANCE AND
TURN OFF GAS
Remote Control:
1. Push the OFF button on the remote once See
page 31).
2. Remove valve access panel.
3. Turn the ON/OFF switch on the valve to OFF.
4. Replace valve access panel.
5. Turn the gas supply valve to the off position.
Manual Mode:
1. Remove valve access panel.
2. Turn the Main Valve Knob clockwise to OFF.
3. Turn the ON/OFF switch on the valve to OFF.
4. Replace valve access panel.
5. Turn the gas supply valve to the off position.
FINAL CHECK
Observe several complete cycles to ensure proper
operation. During these cycles the electronics will
determine the optimum ignition sequence timing.
Log Set Placement
Place only the ceramic log set supplied with the unit
in the firebox. Do not place any other ceramic logs,
wood logs, or other materials in the firebox. If the log
set is damaged or broken contact your dealer for
replacement. The ceramic logs will last a long time;
however, they will break if subjected to rough or
improper handling.
Exact positioning of the log set
is required in order to obtain a pleasing flame
pattern and efficient combustion.
Incorrect log
placement may cause carbon build-up; excess
thermal stress on the log set and stove parts, reduced
efficiency, and high levels of carbon monoxide. If the
log set does not fit into the firebox exactly as outlined,
contact your dealer for assistance.
Installation of the Log Set
(Refer to the following images in this section for log
set assembly)
1. Remove the packaging material around the log
set assembly. Be careful not to damage the log
set when unpacking.