dimmer includes mains power together with
batteries in the receiver for automatic backup in
case of power outage.
•
Without using a mains adapter, battery
replacement is recommended at the beginning of
each heating season.
*
Only the Mertik Maxitrol AC Mains Adapter or one preapproved by
Mertik Maxitrol can be used. Use of other adaptors can render the
system inoperable.
STARTING THE APPLIANCE
Remote Control Operation
A code is selected automatically for all Mertik Maxitrol
electronics from among 65,000 random codes
available. The receiver has to learn the code of the
handset:
Press and hold the receiver’s reset button
(see Figure
41)
until you hear two (2) beeps. The first beep is
short and the second beep is long. After the second
beep, release the reset button.
Within the subsequent 20 seconds press the Small
Flame button on the handset until you hear two
additional short beeps confirming the code is set. If
you hear one long beep, this indicates the code has
failed or the wiring is incorrect.
NOTE: This is a one-time setting only and is not
required after changing the batteries of the handset
or receiver.
Figure 41
– Receiver Reset Button Location
Manual Ignition/Operation
1. Remove orange ignition wire from Control
module and insert onto Piezo Ignitor Connection
on valve top (
see Figures 13 and 16).
2. Open the gas supply to the valve.
3. Remove the access panel from the front of the
stove and set on a non-marring surface.
4. Locate and turn the MANUAL Knob on the valve
clockwise to t
he “MAN” position (see Figure 18).
5.
Turn the Main Valve knob to “OFF”.
6. Using a pen or other device that will reach
through the MANUAL Knob cutout, gently press
the pilot button and hold it in the down position.
7. After a ten second wait, push the piezo igniter
button on the valve every three seconds until you
see the pilot light. If the pilot does not light after
one minute, release the pilot button and wait 5
minutes for gas to clear then repeat step 5. If the
pilot has not ignited after three attempts at the
ignition sequence, STOP ALL ATTEMPTS TO
LIGHT PILOT AND CALL AN AUTHORI ZE D
SERVICE TECHNICIA N.
8. If the pilot lights, continue holding the Pilot Button
for one (1) minute. Release the Pilot Button and
the pilot flame should remain on. If it does,
proceed to step 8. If the pilot flame does not
remain on after you release the Pilot Button,
repeat steps 5 and 6 above. If the pilot does not
remain on after three attempts, STOP ALL
ATTEMPTS TO LIGHT PILOT AND CALL AN
AUTHORIZE D SERVICE TECHNICIAN.
9. Once the pilot flame has been established, turn
the Main valve knob counter-clockwise. The
main burner will ignite after the Main Valve knob
is turned past the minimum setting. Once the
main burner is on, continue turning the Main
Valve knob until the desired flame height is
reached.
10. If the Main Burner does not ignite, return the Main
Valve knob clockwise back to “OFF” , wait three
(3) minutes and repeat step 8. If the main burner
does not ignite after a repeat attempt, STOP ALL
ATTEMPTS TO LIGHT THE MAIN BURNER,
TURN THE MANUAL KNOB TO ON, SHOT OFF
THE GAS SUPPLY VALVE AND CALL AN
AUTHORIZE D SERVICE TECHNICIAN.
11. Once the main burner is ignited, replace the
access panel. Further adjustments to the flame
height are controlled by turning the Main Valve
knob clockwise for less flame and counter -
clockwise for more fire.