![Hearth & Home pelpro PP130 Service Manual Download Page 41](http://html1.mh-extra.com/html/hearth-and-home/pelpro-pp130/pelpro-pp130_service-manual_2114407041.webp)
41
06/21
8390-016A
NO POWER
CHECK THE WALL
OUTLET FOR POWER
RESET THE
THE APPLIANCE.
DISCONNECT FROM
WALL POWER AND
RESET THE SNAP
SWITCH BY PRESSING
THE MANUAL RESET
BUTTON IN THE
CENTER OF THE
SWITCH
IS THE FUSE IN THE
CONTROL
BOARD GOOD? UNPLUG THE
APPLIANCE AND REMOVE
FUSE FROM CONTROL PANEL
TO CHECK IF IT IS GOOD.
TOUCH MULTIMETER LEADS
TO BOTH ENDS OF THE FUSE
IN “Ω” MODE. GOOD FUSE
WILL SHOW LESS THAN 1 Ω.
SYSTEM
IS REPAIRED
IS THE SNAP
DISC ON THE
AUGER TUBE
TRIPPED?
YES
NO
IS THE
APPLIANCE
FUNCTIONING?
MAKE THE REPAIR
BY EITHER FIXING
THE CONNECTION
OR REPLACING THE
COMPONENT.
CHECK WIRE
CONNECTIONS
GOING INTO
THE CONTROL
BOARD.
REPLACE THE
CONTROL BOARD
WIRE HARNESS HAS
TO BE INSPECTED FOR A
SHORT. CONTROL BOARD
MAY ALREADY BE DAMAGED
NO
YES
BAD
GOOD
NO
YES