19
06/21
8390-016A
PP70 & PP130-B APPLIANCES
CONVECTION BLOWER TROUBLESHOOTING
CONVECTION BLOWER NOT COMING ON
WARNING
Exposed Skin, Electric Shock Hazard
Unit must be connected to power for some
troubleshooting steps.
DO NOT
allow
energized connections to touch appliance
body.
APPLY HEAT TO
EXHAUST SENSOR
IS THE EXHAUST
PROBE SENSOR
WORKING?
IS THE EXHAUST
PROBE SENSOR
SECURED TO THE
EXHAUST BLOWER?
SYSTEM
IS REPAIRED
IS THE
BLOWER
RUNNING?
YES
NO
REPLACE THE
.
SEE EXHAUST
PROBE TESTING
CHECK BLOWER
WIRE CONNECTIONS
CHECK VOLTS TO
BLOWER. IS THERE
60 VAC OR HIGHER?
YES
NO
YES
NO
REPLACE THE
CONTROL BOARD
YES
NO
REPAIR THE PROBE
MOUNT LOCATION.
REPLACE THE PROBE
Testing Locations & Readings on next page.