![Hearth & Home pelpro PP130 Service Manual Download Page 31](http://html1.mh-extra.com/html/hearth-and-home/pelpro-pp130/pelpro-pp130_service-manual_2114407031.webp)
31
06/21
8390-016A
3 FLASHES: AMBIENT PROBE ALARM
LOCATE THE AMBIENT
PROBE CONNECTION ON
THE CONTROL BOARD
UNPLUG THE
PROBE, INSPECT
THE CONNECTION &
CHECK ENTIRE WIRE
FOR DAMAGE
SYSTEM IS
REPAIRED
IS THE WIRE
PLUGGED INTO
THE BOARD?
YES
NO
MAKE THE REPAIR
BY REPLACING THE
PROBE OR FIXING THE
CONNECTION.
DID THE ALARM
CODE GO AWAY?
PLUG THE PROBE
BACK INTO THE
CONTROL BOARD.
YES
NO
NO
YES
DID THE ALARM
CODE GO AWAY
AFTER PLUGGING THE
PROBE BACK IN?
TECH TIP:
THE PROBE WILL SENSE TEMPERATURE IN THE ROOM.
IF THE APPLIANCE IS CYCLING TOO MUCH, MOVE THE
PROBE FARTHER AWAY FROM THE APPLIANCE.
Testing Locations and Readings on next page.