9/15/2011 Hearth & Home Technologies ©
Page7
System Basics
IntelliFire Plus Troubleshooting
#1
#2
#3
#1
#2
#3
ON/OFF/REMOTE switch on module must
be in REMOTE position for wireless con-
trols to operate the remote and optional
wired wall switch.
The wireless control and receiver (housed
in the control module) communicate to and
from each component via radio frequency.
They must remain within 30 feet of each
other.
For the RC300, when in thermostat mode,
transmission of information happens every
60 seconds. For optimum operation you
may need to try different locations for the
wireless control when in thermostat mode.
If a wired wall switch is installed and in the
ON position, it will override the commands
of the wireless controls. Must be OFF to
use remote.
#4
#4
AUX200 & 300 module controls the
FAN and incorporates timer and
rheostat functionality.
AUX300 module also controls 2
auxiliary functions. AUX1 offers
high/med/low settings
AUX2 offers ON/OFF control.
From the wireless control commands, data
signals are transmitted to the AUX200 &
300 modules. Voltage is sent to igniter,
stepper motor, pilot regulator and main
burner regulator.
Eliminate wireless controls
from the system when
troubleshooting system by
“unlearning remote.
Wireless
Controls