Problem Scenarios #2
IntelliFire Plus Troubleshooting
Problem: The module makes sparking noise, but no spark * **
The problem may be:
1. Loose or improper wiring
2. System is not grounded
3. Igniter wire is loose or disconnected
4. Improper gap between igniter and pilot hood
*
Troubleshooting assumes the wireless controls & battery backup have been eliminated from the system. To do
this the remote must be ―unlearned‖ from the system.
** IntellifFire Plus IPI ignition module emits beeps during operation. The noise referred to in this section is noise
from the module ignition coil which creates voltage for pilot igniter.
Go to page 29 to familiarize yourself with
module diagnostic codes.
** Notice **
Disconnect power to the system
prior to disconnecting any compo-
nents by switching the ON/OFF/
REMOTE module switch to the
OFF position. Interrupting power to
stepper motor can freeze motor po-
sition (see page 29).
It is not recommended to operate
the ignition control module with
disconnected wire connections. A
short could cause permanent dam-
age.
Introducing the pilot sensor rod with
a false flame, such as from a flame
stick, will cause the module to go
into lock-out mode. This is due to a