background image

 

 

Source Capture 

Fan-Filter Exhauster System 

 

HA-SCE-G1 

Owner’s Manual 

Table of Contents 

HealthyAir® HA-PF7-1111 Filter 

Important Safety Instructions 

Technical Specifications 

Packaging Reference 

Component Reference 

Assembly Instructions 

6-7 

Assembly Instructions 

– Extraction Hose 

Assembly Instructions 

– Pop-Up Source Capture Vent 

9-10 

Assembly Instructions 

– Outside Vent Adapter Kit 

11-13 

Operation Guidelines 

14-15 

Filter Replacement 

16-18 

Maintenance 

19 

Basic Service and Troubleshooting 

20-24 

Electrical Wiring Schematic 

25 

1-Yeart Limited Warranty 

26 

Product Registration Form 

27 

 

Healthy Air Inc. 

800-259-2535 

www.HealthyAir.com 

Summary of Contents for HA-SCE-G1

Page 1: ...e 5 Assembly Instructions 6 7 Assembly Instructions Extraction Hose 8 Assembly Instructions Pop Up Source Capture Vent 9 10 Assembly Instructions Outside Vent Adapter Kit 11 13 Operation Guidelines 14 15 Filter Replacement 16 18 Maintenance 19 Basic Service and Troubleshooting 20 24 Electrical Wiring Schematic 25 1 Yeart Limited Warranty 26 Product Registration Form 27 Healthy Air Inc 800 259 2535...

Page 2: ...1 HealthyAir Model HA SCE G1 Source Capture Fan Filter Exhauster System with HealthyAir HA PF7 1111 Filter at www HealthyAir com ...

Page 3: ...r the following conditions When not in use for a long period of time When cleaning servicing the machine or during replacement of filters When moving the air purifier To prevent electric shock do not dismantle repair or modify this product Maintenance and cleaning instructions should be followed exactly as directed in this manual In case of malfunction please contact an authorized distributor or H...

Page 4: ...tions Model Number HA SCE G1 W B G Rated Voltage 120V 60HZ Power Consumption 200W Weight 37 lbs 17 kg Base Dimensions 14x12x24 in 350 310 615 mm Flex Hose Length 45 in 114 3 cm Air Flow Rate 240 cfm 400 m 3 h Noise Level 56 dB ...

Page 5: ...follows Carton 1 1 Air Purification Unit with 1 Pocket Filter 4 Wheel Casters 1 Acoustic Mat 1 Manual 1 Remote Control 1 Power Cord 1 Screwdriver Carton 2 3 1 2 Extraction Hose Hood 1 2 Hose Clamp 1 2 Grill LED Cable LED Bulb Optional 1 Outside Vent Adapter Kit Outlet Flange Base Blank Off Plate Back Panel Optional ...

Page 6: ...ilter HA PF7 1111 12 Hose Clamp 13 Safety Switch 14 Capacitor 15 PCB Board 16 Extraction Hose 17 LED Light Bulb Option 18 Hood 19 G4 Bulb Mount Option 20 LED Grill Option 21 LED Cable Plug Option 22 LED Cable Socket 23 Top Cover 24 Control Panel Display 25 Control Panel 26 Thumb Screw 27 Access Door 28 Power Cord 29 Remote Control 30 Base Blank Off Plate Optional 31 Outlet Flange Optional ...

Page 7: ...4 5 1 1 Place the unit on its side on a flat surface as shown in Fig 1 5 1 2 Locate the four 4 Caster Wheels and the Screwdriver that are provided in Carton 1 5 1 3 Unscrew and remove the screws that are pre mounted onto the Base Plate on the bottom of the unit There are four 4 screws per wheel for a total of sixteen 16 screws 5 1 4 Align the holes of the Caster Wheel Mount with the holes on the B...

Page 8: ... the center of the Grill 5 2 2 Connect the LED Cable to the LED Light Bulb by sliding the two 2 prongs of the bulb into the G4 Bulb Mount 5 2 3 Pass the 52 LED Cable through the Hood and entire length of the Extraction Hose such that the LED Cable Plug passes through the bottom of the Extraction Hose 5 2 4 Connect the Grill to the Hood by snapping the Grill onto the rim of the Hood as shown in Fig...

Page 9: ... end of the Extraction Hose over the Inlet Port as shown in Fig 3 If the diameter of the Extraction Hose needs to be increased rotate the end of the hose counterclockwise 5 3 2 Hold the end of the Extraction Hose and rotate it clockwise to reduce its diameter to fit it to the diameter of the Inlet Port 5 3 3 Position the Hose Clamp at the base of the Extraction Hose and screw the hex nut to tighte...

Page 10: ... the system is in use When inactive the vent may be Pushed down to hide it from view The result is a system that offers increased collection efficiency optimized airflow aesthetically appealing design and simplicity of use Note that the HealthyAir Source Capture Fan Filter Exhauster System can either be set to exhaust in the room as a Recirculating Ventilation system or exhaust to outside as an Ou...

Page 11: ...10 V Assembly Instructions 5 4 Install Pop Up Source Capture Vent Optional Fig 4 Pop Up Vent Integration for Recirculating Ventilation Fig 5 Pop Up Vent Integration for Outside Ventilation ...

Page 12: ... unit which is capable of exhausting filtered air out of the facility with connection to exhaust ducting To add this feature visit www HealthyAir com and select Outside Vent Adapters from the Accessories tab in the Products dropdown menu The Outside Vent Adapter kit comes with one 1 Outlet Flange and one 1 Base Blank Off Plate as shown in Fig 6 Fig 6 Outside Vent Adapter Kit Outlet Port Base Blank...

Page 13: ... Ventilation as described in Section 6 1 remove each Caster Wheel from the Base Plate and set aside the wheels and the mounting screws 5 5 2 Turn the unit upside down and position the Base Blank Off Plate over the Base Plate 5 5 3 Position the Base Blank Off Plate such that the bolt pattern for the Caster Wheels on the Base Blank Off Plate aligns with the bolt pattern on the Base Plate 5 5 4 Re in...

Page 14: ...ge on the Outside Vent Outlet as shown in Fig 8 5 5 6 Connect a standard 4 diameter Exhaust Duct not supplied to the Outlet Flange and use a standard hose clamp to secure the connection 5 5 7 Run the Exhaust Duct out of the facility per applicable IMC codes Fig 8 Outlet Flange Installation Outlet Flange ...

Page 15: ...n on and display a red light 6 2 2 Activate the unit by pressing the Power button located on the Control Panel shown in Fig 6 or on the Remote Control Once the unit is powered the motor will start with the Fan Speed set to the Mid Speed 6 3 Source Capture System Controls Each of the respective control elements shown on the Control Panel Display in Fig 6 work as follows SPEED button on Control Pane...

Page 16: ...R button is pressed five 5 times such that it passes through the complete timing schedule it will run continuously until the unit is manually turned off LIGHT button on Control Panel and Remote control turns the LED Light on and off When the LED Light is on the symbol above the button turns green Pressing the LIGHT button once more will turn off the LED Light as well as the indicator light FILTER ...

Page 17: ...ial warranty claim 7 2 Filter Change When the unit has been in operation for 400 hours the Filter Change indicator light on the Control Panel will begin to flash indicating that the filters must be replaced as follows Note Depending on usage and contaminates in the environment the filter may need to be replaced before the 400 hour default cycle expires Contact a representative to determine if you ...

Page 18: ... in Fig 8 7 2 5 Reinstall the Access Door ensuring that the Access Door is properly inserted back into its track Once the Access Door is properly aligned and set in place secure it by screwing in the Thumb Screws 7 2 6 Plug the Power Cord back into the Power Socket and wall socket Fig 8 Replacement Filter Installation Pocket Filter HA PF7 1111 Filter Compartment ...

Page 19: ... Cord from the Power Socket wait a couple seconds and plug the Power Cord back into the Power Socket 7 3 2 Press and hold down the Power Button on the Control Panel not the Remote Control for five 5 seconds 7 3 3 After five 5 seconds has passed release the Power Button The filter change timer will have reset to 400 hours and the Filter Change indicator light will have stopped flashing now Fig 11 F...

Page 20: ...uring the filter replacement process If debris has accumulated in the Filter Compartment clean the interior of the unit as follows 8 2 1 Turn the Power Off unplug the Power Cord from the Power Socket remove the Access Door and remove the filter from the unit 8 2 2 Vacuum and remove any debris that has accumulated in the filter compartment and adjacent accessible areas of the interior of the unit 8...

Page 21: ...y licensed electrician Possible Cause Solution Blown Fuse Replace the Fuse Safety Switch not engaged Properly close the Access Door Safety Switch malfunction Replace the Safety Switch HV Board malfunction Replace the HV Board PCB Board delay function Unplug and re plug Power Cord 9 2 Air Purification System Power is On but Unit is Inoperable If the unit powers on but fails to operate properly the ...

Page 22: ...ion Replace the PCB Board 9 4 Fan Speed Cycle Error If the unit does not properly cycle through all three 3 fan speed settings or the unit shuts off when cycling through the fan speed settings the issue may be the result of one of the following causes Contact the manufacturer for the Control Panel reset instructions If that does not resolve the issue the unit will require service by the manufactur...

Page 23: ...ockwise Loose Flex Hose connection Tighten Hose Clamp 9 6 Flex Hose Unravels If the Flex Hose is lengthened expanded or bent past its tolerance point the hose may come apart and unravel The issue may be the result of one of the following causes and may require replacement parts Possible Cause Solution Expanded past tolerance Reconnect or replace Flex Hose Lengthened past tolerance Reconnect or rep...

Page 24: ... Mount is faulty Replace LED Cable LED Bulb is burnt out Replace LED Bulb 9 8 Remote Control is Inoperable If the Remote Control fails to operate the unit the issue may be the result of one of the following causes and may require replacement parts or service by the manufacturer or a professionally licensed electrician Possible Cause Solution Battery nearly exhausted Replace batteries Remote Contro...

Page 25: ...s and may require filter replacement Possible Cause Solution Pocket Filter is fully loaded Clean or Replace Pocket Filter Flex Hose connection is loose Secure Flex Hose to Inlet Port 9 10 Filter Change Indicator Light is Flashing If the unit is properly functioning and the Filter Change indicator light is flashing the default filter change timer has expired and the filter should be replaced Possib...

Page 26: ...25 X Electrical Wiring Schematic Fig 10 Electrical Wiring Schematic ...

Page 27: ...all other or additional warranties whether written or oral expressed or implied including but not limited to warranties of merchantability workmanship or fitness for a particulate purpose Retain proof of purchase and the original box and packing materials Exclusions to the Warranty This Limited Warranty does not apply or is void as to any product or part damaged by 1 accident misuse abuse or lack ...

Page 28: ...ompleted form via email by sending a scanned image or photograph to Sales HealthyAir com Note that the Model Number and Serial Number are written on the sticker located at the bottom of the side panel of the unit Please contact us at 800 259 2535 or visit www HealthyAir com for Customer Service and Orders Name Business Name Street Address City State Zip Phone Number Email Address Date of Purchase ...