Trouble Shooting Guide for the PhysioStep LTD
Malfunction
Cause
Solution
The Display does not turn on
when pedaling lightly.
1. Console wire is disconnected
or connected improperly.
2. Low Batteries in the Display
3. Damaged Console Control
Wire
4. Damaged Generator, Console
PCB or Control PCB
5. Unit not plugged into wall
outlet
1. Detach and Re-connect
console wires to make
sure they are connected
properly.
2. Replace the Batteries in
the Display
3. Replace any damaged
Wires, Control Panels or
Generators
Console Works well but
resistance value is zero
1. Brake Control Wire is
improperly connected or
damaged.
2. The Console PCB or Low
Control PCB may also be
damaged.
1. Detach and Re-connect
brake control wires to
make sure they are
connected properly
2. Replace Damaged Power
Board if needed.
Meter does not display the
RPM Value.
1. Damaged Generator or Lower
Control PCB
1. The component will need to
be repaired or replaced by a
qualified technician.
Heavy resistance when you
begin pedaling
1. Remove the Console Control
Wires, if there is now less
resistance it may be caused
by a wrong VR Default Value.
2. Remove the Console Control
Wires, If it still has heavy
resistance when pedaling it
may be a damaged Lower
Control PCB
1and 2. In both cases, this
component will need to be
repaired or replaced by a
qualified technician.
Warranty Information:
*
Designed for home or Institutional Settings where usage is less than 5
hours per day.
Serial # (Printed on Original Box):________________________
Purchase Date:___________ Purchased From: ___________
3 Year Parts Warranty, One Year Labor, Lifetime Frame