H B X Z O N - 0 5 5 0 Z o n e C o n t r o l
V e r s i o n 2 . 0 2
Page 16
Advanced Settings
Enter the contractor code in location settings from the home screen menu to
unlock advanced settings. Contact HBX Tech Support for contractor code.
special functions
1. Thermostat Type: select between multiple heating, cooling and a variety
of combined modes: 1H, 1C, H/C, 2H, 2C, 2H/1C, 2C/1H, 2H/2C.
2. Setbacks: This option allows you to turn on/off setbacks.
3. Geo Mode: This option allows you to turn on Geo Mode to control 2 pipe
systems for geothermal applications. This will change the demand outputs
for a heat (HD) and cool (CD) demand.
fancoil settings
1. Fan On With Demands (W,Y): This option will turn on the fan with any
fancoil demand.
2. Zone On with Demands (W,Y): This option will turn the corresponding zone
pump on with any fancoil demand.
3. Temperature Averaging: This option will average the temperature between
thermostats.
4. Damper Zone: This option allows you to set the selected zone as a damper
or second stage damper.
Damper - off
: No damper being utilized in current
setup.
Damper - single n/o:
Corresponding zone output is
utilizing normally open dampers.
Damper - single n/C:
corresponding zone output is
utilizing normally closed dampers.
Dampers - 2 stage n/o:
1st stage is radiant and the
second stage is utilizing a normally open damper.
Utilizing this option will require to use the next
corresponding zone output to accommodate for the
second stage damper. This option is only available for
Zones 1 and Zone 3.
Dampers - 2 stage n/C:
1st stage is radiant and the
second stage is utilizing a normally closed damper.
Utilizing this option will require to use the next
corresponding zone output to accommodate for the
second stage damper. This option is only available for
Zone 1 and Zone 3.
5. 4-Pipe System: This option is displayed when Geo Mode is turned on. This
allows you to control a 4 pipe system for geothermal applications.
100%
9:41 AM
Thermostat Type
Setbacks
View All
View Auto
Degrees C
Geo Mode
Fan On with Demands(W,Y)
Zone On with Demands(W,Y)
Temperature Averaging
Damper Zone
Heat/Cool
SPECIAL FUNCTIONS
FANCOIL SETTINGS
MODE SETUP
None
Off
Thermostat Mode
Room
Sensor Type
None
Advanced Settings
83°F
100%
9:41 AM
Thermostat Type
Setbacks
View All
View Auto
Degrees C
Geo Mode
Fan On with Demands(W,Y)
Zone On with Demands(W,Y)
Temperature Averaging
4-Pipe System
Heat/Cool
SPECIAL FUNCTIONS
FANCOIL SETTINGS
MODE SETUP
None
Thermostat Mode
Room
Sensor Type
None
Advanced Settings
83°F
100%
9:41 AM
Off
Single N/O
Single N/C
2 Stage N/O
2 Stage N/C
Damper Zone
83°F
With Geo Mode on