Safety instructions
6
A4722-1.0
HBM: public
CX22B-R
Installation of the module(s)
SomatXR modules are IP65/IP67 rated. They can be
used outdoors without any special protection. In dirty
environments, protective caps should be attached to con
nectors that are not being used to allow later plug inser
tion.
SomatXR modules can be used as tabletop unit but also
mounted on a surface or in a box.
Please consider following conditions at the place of
installation:
S
Observe the maximum permissible ambient tempera
tures given in the specifications.
S
Minimize device exposure to direct sunlight in hot
operating environments.
A module must not be connected directly to a power sup
ply network. The maximum permissible supply voltage is:
Module
Power supply
CX22B-R
10 V
DC
… 30 V
DC
CX23‐R
10 V
DC
… 30 V
DC
EX23‐R
10 V
DC
… 36 V
DC
MX modules
10 V
DC
… 30 V
DC
Notice
The module must not be connected directly to the power
supply system.