Mechanical installation
12
A05569_01_X00_00
HBM: public
AD105D
4
Mechanical installation
You can install the AD105D in a transducer by mounting the motherboard on
the side of a transducer, for example. Ask HBK for a suitable shielding plate, if
necessary.
You must use a shielded housing and shielded cable if you do not mount the
AD105D within a closed (electrically conductive) transducer housing.
Notice
The AD105D is not protected against electrostatic discharges (ESD). Static
discharges can destroy the electronics.
Therefore ensure you have discharged any static charges before touching the
motherboard parts or connections.
Important
Before installing
several
transducer electronics modules in a plant with a bus
system, please note the following:
Before
establishing a connection to the bus system, connect the transducer
electronics
individually to a PC to set different addresses.
Dimensions
Dimensions in mm
41.7
2x
∅
2.5
3.3
3.3
19.2
45
22.5
Height of motherboard
including equipment:
7 mm