background image

15

Use Only Genuine Hayward Replacement Parts.

Replacing Parts

Sweep Hose

• Sweep Hose Wear Rollers will experience wear when

operating in a plastered or concrete pool.

• When the Wear Rollers wear-down to the outer groove

(Wear Line) replace the Wear Rollers (P/N AEX5006A).

• Check the Sweep Hose for holes.

Some parts will wear with normal use. To insure the

high quality performance, insist on

Genuine Hayward

replacement parts (using non-Hayward replacement

parts will Void the Viio Cleaner’s Warranty).

The following parts are user replaceable and subject to

normal wear and tear.

1. Sweep Hose:

If a hole forms in the Sweep Hose, it

should be replaced. Unscrew the mender nut from the

hose and pull the Sweep Hose off the Cleaner Connector.

Attach a new Sweep Hose to the Cleaner Connector.

(Replacement Part Number: AEX6000RSHA)

2. Debris Bag:

The Debris Bag should be replaced if it

is torn.

(Replacement Part Number: AEX5500BFA)

3. Swivels:

If a swivel ceases to turn easily or leaks

while the cleaner is running, it should be replaced.

(3-Pack Replacement Part Number: AEX5000SA)

Storing the Viio Cleaner

1. Turn the Booster Pump OFF

and set the timer so

the Booster Pump will not turn on while the Viio

cleaner is out of the pool (

Never

operate the

Booster Pump without the cleaner connected).

2.

Disconnect Wall Quick Connect from the Universal Wall

Fitting. The Universal Wall Fitting may be left in place.

3.

The cleaner is constructed of the finest materials

available, however we recommend that when the Viio

cleaner is removed from the pool, it should be stored

flat on its wheels in a shaded area to protect the unit

from excessive exposure to ultraviolet solar rays.

4. Store the Sweep and Pressure Hoses straight and

flat,

not coiled

. If possible, store the hoses in the

shade.

Winterizing the Cleaner

When closing your pool for the winter completely drain

the water from the Viio Cleaner (by slowly rotating it in

all directions) and Hoses. Store the Viio Cleaner indoors
to prevent freezing the inner mechanisms.

Periodic Freezing Conditions

If you are in an area subject to periodic freezing

conditions, but pool equipment is kept in operation, it is

very important that the filtration system and Viio cleaner

be in operation during times when hard freezing occurs

(normally between 3AM and 7AM). Running the Viio

cleaner at this time will insure against damaging the

Cleaner and may prevent freezing of pool water.

Wear Roller

Wear Line (outer

groove)

Summary of Contents for Viio Turbo AE5500

Page 1: ......

Page 2: ......

Page 3: ...anty Always disconnect and remove the Viio cleaner and hoses from the pool before cleaning or backwashing the pool filter After cleaning or backwashing the pool filter allow the filtration system to run for a minimum of five minutes or until all debris has been flushed from plumbing lines before reconnecting the Viio cleaner New plumbing lines must be flushed out before connecting the Viio cleaner...

Page 4: ... Operating the Viio Cleaner 9 Setting Pressure 9 Large Capacity Debris Bag 10 Correctly Operating Cleaner 11 Cleaner Adjustments 12 Changing Spin Out Frequency 12 Adjusting Spin Out Duration 12 Adjusting Sweep Hose Power 13 Maintenance 14 Removing the Viio Cleaner from Pool 14 Emptying Debris Bag 14 Cleaning the Cleaner Connector Screen 14 Sweep Hose 14 Replacing Parts 15 Sweep Hose 15 Debris Bag ...

Page 5: ...y design offers the following features Faster Cleaning Wider Vacuum Nozzle Powerful Sweep Hose Complete Pool Coverage Patented AquaDrive water jet propulsion Randomized Cleaning Backup Spin out Large Debris Pick up Larger Suction Inlet Three High Pressure Water Jets Less Frequent Bag Cleaning Larger Capacity Bag Easy to remove clean and replace debris bag Less Wear on Pool Surface Patented AquaDri...

Page 6: ...stment Knob F Cam Cap G Rigid Pressure Hose H Hose Float I Hose Pipe Coupling J Hose Swivel See special installation instructions in this manual K Adjustable Wall Quick Connect L Sweep Hose M Wear Roller N Rigid Hose Pipe O Universal Wall Fitting Q In Line Filter R Hose Swivel Assembly S Hose Cleaner End Assembly T Hose Wall End Assembly U Setup Pressure Gauge Wall Quick Connect Rearview Product C...

Page 7: ...and vacuum new surface debris before installing the Viio Pools with Excessive Sand Pools with excessive amounts of sand dense debris should be vacuumed manually before installing the Viio The Viio Bag has a larger mesh area toward the bottom of the bag that allows sand in excess of 1 cup to pass through the bag This feature enables the Viio to continue to operate picking up leaves acorns grasses e...

Page 8: ... Wall Fitting part O and Teflon tape from Bag 1 5 When installing or re installing the Universal Wall Fitting use Teflon tape on its plastic threads Leave two starting threads on the end of the Universal Wall Fitting un taped 6 Screw the Universal Wall Fitting into the Dedicated Return Line Important Turn the Universal Wall Fitting 1 full turn to the right to engage starting threads Be sure both p...

Page 9: ...he end of the tape marked Wall Connector End on the pool coping immediately above the Universal Wall Fitting 6 Unroll the Measuring Tape walk around the pool to the farthest point along the pool wall from the Universal Wall Fitting At the farthest point from the Universal Wall Fitting holdthe Measuring Tape at the pool edge coping and read the number of Pipe Assemblies specified on the tape Rigid ...

Page 10: ...he Wall Quick Connect into the Universal Wall Fitting and turn it to the left counter clockwise to lock The hose should be on the bottom below the adjustment knob 2 Pull the Wall Quick Connect outward to check that the Wall Quick Connect is locked into the Universal Wall Fitting 3 To disconnect the hose first turn the Booster Pump and Filtration pump OFF then push the Wall Quick Connect toward the...

Page 11: ... the hole in the Setup Pressure Gauge or by the Sweep Hose Never point a jet or hose at people or pets Clip the Setup Pressure Gauge to the hose near the Wall Quick Connect 1 Turn the filtration system pump ON then the Booster Pump ON Read the pressure on the Setup Pressure Gauge connected to the Cleaner Connector Use a flat blade screwdriver to adjust the Wall Quick Connect Knob see figure 2 unti...

Page 12: ...ed 2 Slide Float Closure off of bag figure 3A 3 Hold open edges apart and shake debris from bag figure 3B 4 Slide Float Closure onto bag Sand dense debris Always empty the Viio bag when sand or heavy debris fills the bag up to the Empty Sand Line The Viio will continue to operate with 1 cup of sand and the remainder of its bag filled with debris Note Pools with excessive amounts of sand should be ...

Page 13: ...om below the cleaner and passed through the vacuum tube into the Debris Bag where it is held until the user empties the Bag Viio may not pick up all debris on the first pass but your pool should be clean in 3 hours or less depending on pool size shape and the amount of debris in the pool Observe Viio s operation at regular intervals and empty the bag as necessary Only operate Viio for the time nec...

Page 14: ...gs for more frequent Spin Outs If Viio rarely needs to back up and Spin Out near an obstacle then a cam with fewer prongs and less frequent Spin Outs will increase effective cleaning time Changing Spin Out Cam 1 Turn the Cam Cap to open 2 Turn the Thumbscrew counter clockwise and remove it from the square stem 3 Remove the Spin Out Cam 4 Place the desired Cam in place over the Stem 5 Screw the Thu...

Page 15: ...g if the sweep hose does not move side to side and just drags behind the cleaner check the Sweep Hose for holes Check for debris behind the adjustment screw or in the jet end of the Sweep Hose Sweep Hose Moves Slowly Or Not At All turn the adjustment knob counter clockwise to increase Sweep Hose power Sweep Hose Frequently Sprays Out Of The Pool turn the Sweep Hose adjustment knob clockwise to red...

Page 16: ...aner From The Pool Warning Risk of Injury The Filtration Pump and Booster Pump must be OFF when connecting or disconnecting cleaner or hose 1 Turn the Booster Pump and Filtration Pump OFF If you will not be replacing the cleaner before the next Booster Pump timer cycle turn the Booster Pump Timer OFF Never run the Booster Pump without the cleaner connected Failure to do so can cause serious injury...

Page 17: ...mp OFF and set the timer so the Booster Pump will not turn on while the Viio cleaner is out of the pool Never operate the Booster Pump without the cleaner connected 2 DisconnectWallQuickConnectfromtheUniversalWall Fitting TheUniversalWallFittingmaybeleftinplace 3 The cleaner is constructed of the finest materials available however we recommend that when the Viio cleaner is removed from the pool it...

Page 18: ...16 Use Only Genuine Hayward Replacement Parts Troubleshooting For Technical Assistance Call 33 474 462 476 ...

Page 19: ...ately Viio Turbo Ref No Part No Description 1 SPX6060Z1 Screw 1 4 Type b x 1 1 4 Set of 10 2 SPX6060A Pump Volute 3 SP1500UNPAKE Union Conector Kit 50 mm 4 SPX6050C Impeller Assembly 5 SPX6060S Seal Plate O Ring 6 SPX2700SA Shaft Seal Assembly 7 SPX6060E Seal Plate Assembly incl Drain Plug w O Ring 8 SPX4000FG Drain Plug w O Ring 9 SPX6060G Motor Support 10 SPX3200Z5 Motor Belt 11 SPX0750MSF Motor...

Page 20: ...ut Sweep Hose 16 AEX6000HWA2V Pressure Hose and Top of In Line Filter Assembly 17 AEX6000HFA Hose Swivel Assembly 18 AEX6000HE Rigid Hose Pipe Section 2 Rigid Pipes and 1 Coupling 19 AEX6000HWA1 Wall Quick Connect Hose Bottom In Line Filter Assembly 20 AEX5004L2 Wall Fitting 21 AEX6009S In Line Filter Screen Hose 22 AEX5010G19 In Line Filter O Ring 23 AEX6000RSHA Pressure Hose and Top of In Line F...

Page 21: ... 3 This Limited Warranty shall not apply to any injury loss damage defect or malfunction of the CLEANER or failure of the CLEANER to function resulting from any failure to operate or maintain the CLEANER in accordance with the directions contained in the Owner s Guide provided by HAYWARD or any injury loss damage defect malfunction or failure to function resulting from any misuse unreasonable use ...

Page 22: ...e and serial number of the item claimed to be defective the name and address of the PURCHASER and a brief description of the problems defects encountered Call 0 825 000 549 0 15 min TTC for the name and address of the nearest Factory Service Center HAYWARD will at its option repair or replace all defective CLEANER parts covered by this Limited Warranty at its own cost and expense and return the sa...

Page 23: ......

Page 24: ......

Reviews: