USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
29
pH Extend Enabled
- If enabled, the OmniLogic will continue to run the filter pump regardless of schedule until the pH level in the
pool has reached the setpoint.
Do You Have a Salt Water Chlorine Generator?
(requires Hayward Turbo Cell)
If Yes is selected:
Type of Cell?
Select the type of Hayward TurboCell that is installed in your system.
Where is the Cell Located?
If an entry is already shown in the box, touch the Advance button. If no entry is shown, selecting the box will bring
you to a table showing the detected cell. Select the TurboCell and save.
Percentage of Outpu
t - The OmniLogic can only generate chlorine while the filter pump is operating. Set the percentage of run time that you
desire chlorine generation. Raise this value to generate more chlorine. Lower this value to generate less.
How Many Cleaners?
- This question is for THIS BOW ONLY. For example: If you have 2 cleaners; one for the pool BOW and one for the spa BOW, you
would answer “1” to this question.
If “1”or more is selected:
Select and Configure a Cleaner
At this screen you can add, delete and configure your cleaner(s). Select the desired cleaner, then touch the
Advance button. When finished configuring cleaner(s), you’ll be returned to this same screen. Touch the Save button to save all your settings
and advance to the next section of configuration. Refer to the following information when configuring cleaner(s):
Type of Cleaner?
Touch the box and select the type of cleaner used. Choices are Pressure, Suction, Robotic and In-Floor.
Name of Cleaner -
Touch the box and use the keyboard to name the cleaner.
Does Cleaner Have a Pump?
Select whether the cleaner has a dedicated pump. If so, the OmniLogic will turn this pump on when the cleaner
is scheduled to run.
If Yes is selected:
What Type?
Select the type of pump used. The choices are Single Speed, Two Speed and VSP.
If single speed or two speed pump is selected:
Which Relay is it Wired to?
If using a single speed or two speed pump, you’ll be asked which relay(s) is wired to the
pump. If a value is already shown in the box(es), advance to the next screen. If no value is shown, selecting the box will bring
you to a table showing all detected relays. Select the proper relay(s) from the table and touch the Save button to save. The
relay should now be shown in the box(es) and you can advance to the next screen to continue the pump configuration.
If VSP is selected:
Which Hayward Unique Address?
If using a VSP for your cleaner pump, you’ll be asked what is the Hayward Unique
Address (HUA). If a value is already shown in the box, advance to the next screen. If no value is shown, selecting the box
will bring you to a table showing all detected devices. Select the proper HUA from the table and touch the Save button. The
address should now be shown in the box and you can advance to the next screen to continue the VSP configuration.
Minimum RPM / Maximum RPM -
Set the minimum and maximum desired RPM. Refer to your pump manual for more
information.
Minimum Allowed Pump Speed % / Maximum Allowed Pump Speed % -
The OmniLogic will automatically calculate
these values based on the minimum and maximum RPM that were previously entered. They can be changed is desired.
Speed Presets -
Set the Low Pump Speed %, Medium Pump Speed %, and High Pump Speed %, presets. These presets
will be used when setting schedules for your pump.
Does Cleaner have a Valve?
Select whether the cleaner requires a valve to change position when in use.
If Yes is selected:
How Many?
Select how many valves are used for the cleaner.
Where is the Valve(s) Wired?
Selecting the box will bring you to a table showing all detected low voltage relays. Select the relay(s)
that is wired to the cleaner valve(s), then advance. The valve(s) should now be shown in the box(es). Advance to the next screen to
continue cleaner configuration.
Would you like your valve(s) to cycle On and Off at a set interval?
If you would like the cleaner valve(s) to cycle to a set interval