48
5. Circulation System is Loud
YES
YES
System is
Loud
Vessel
secured to
pad?
NO
Secure
vessel to pad
YES
Booster
pump is
secured to
pad?
Secure
vessel to pad
NO
Needle valve
closed/barely
open?
Vessel is being
bypassed, yet
booster is
running?
NO
Adjust
needle
valve until
noise
reduces
YES
NO
STOP: Shut the
system down &
contact tech
support:
(908) 355-7995
Verify the
booster pump is
correctly wired
YES
Fix wiring
and retest
Is pump
correctly
wired?
NO
Verify the pump is not
experiencing cavitation
(caused by a suction-side
restriction) OR
deadheading (due to a
pressure-side restriction)
Is system still
loud?
YES
NO
Contact Tech
Support:
(908) 355.7995
Problem
solved