High chlorine residuals may cause the UV efficiency reading to be lower than
expected. An imbalance in water chemistry should be corrected before replacing
hardware.
Test the water chemistry, following the table on page
14. High levels of chlorine can lower lamp readings. IF
water chemistry is not fully balanced, correct this and
retest (30 minutes). IF chemistry is balanced, proceed
to step 1D.
Press & hold the menu button, until the ‘CLr’ appears.
Press the down arrow repeatedly until ‘run’ appears,
then press enter. IF service hours are 9,000
*
(900.) or
greater, replace lamps. IF not, contact tech support
(908) 355.7995.
Test Chemistry
Step 1C
Step 1D
Verify Lamp Run Hours
29
1. ‘SYS ERR’ Appears on Display (cont.)
*NOTE: Lamp hours will appear in standard units up to 999 hours. Numbers greater
than 999 will appear in tens, with a decimal at the end (for example 1,000 hours will
appear as 100.).