23
Pro Tip: Disconnecting the vessel sensor cable before the lamps will provide more
room to access the lamp connections for removal.
Disconnect the three Ozone tubes from the
Ozone manifold (tubes are fixed to lamps).
Disconnect the lamp sensor located in the
center of the vessel cap (counterclockwise).
Remove lamps
*
, rotating the base connection
counter-clockwise and pull lamps straight out.
*
Disconnect lamps from ballast cables,
followed by the interlock sensor.
Step 5
Step 6
Step 8
Step 7
*IMPORTANT: Always wear included gloves when handling lamps, DO NOT touch the lamps
with bare hands.
Cleaning Quartz Sleeve & Lamp Sensor (cont.)