![Hayward hydrorite uvo3 Troubleshooting Manual Download Page 32](http://html1.mh-extra.com/html/hayward/hydrorite-uvo3/hydrorite-uvo3_troubleshooting-manual_2111082032.webp)
YES
32
2. Display Not Lit
Display Not Lit
Test power to
display, is power
less than 5VDC?
NO
YES
Replace
the display
NO
Test main board
input power for 192-
288VAC off
interconnect board
Test the 1A
display
power fuse
Transformer
output shows
192-288VAC?
Both
transformer
inputs show
108-132VAC?
YES
Replace
Transforme
r
Test
interconnect
board fuses
Is power
correct?
Verify source
power, is 108-
132VAC
present?
NO
Resolve
source
power issue
YES
Replace
fuse &
retest
Is the
fuse
blown?
YES
NO
Replace
main PCB
YES
Replace
interconnect
board
NO
NO
Are fuse(s)
blown?
NO
YES
Replace
interconnect
board
Verify
voltage
selectors are
correct
Verify
voltage
selectors are
correct
Did the
fuse blow
again?
YES
NO
Replace
board with
affected
fuse
Problem
solved
Summary of Contents for hydrorite uvo3
Page 7: ...HydroRite UVO3 Overview ...
Page 10: ...10 HydroRite Vessel Top ...
Page 17: ...HydroRite UVO3 How To ...
Page 26: ...HydroRite UVO3 Troubleshooting ...