HEATPRO HEAT PUMP
HP13023770 Rev: E
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908.351.5400 www.haywardpool.com
Display Diagnostic Codes -Troubleshooting Guide for Hayward HeatPro Heat Pump
Display Problem
Possible
Cause
Solution
No power to heat pump
Tripped circuit breaker/
no power supply
Check breaker and ensure that the unit is properly
installed.
Faulty electrical
component
Call for service.
(blank)
Unit will not turn on
5-minute delay
Wait 5 minutes.
Check water flow to heat pump.
Clean your filter
Make sure all valves are fully open and bypass
valve is closed.
Ensure pool filter pump is on.
Normal operation for TCO function
PS
Water Pressure Switch
Low or no water flow
Turn off fountains, etc.
Air flow obstruction
Call for service.
LP
Low Pressure Switch
Low Ambient
Temperature cutoff
Wait for outside temperature to reach 60
°
F.
Check water flow to heat pump.
Clean your filter
Make sure all valves are fully open and bypass
valve is closed.
Low water flow
Ensure pool filter pump is on and turn off
fountains.
Set unit to “ACP” if using heat / cool option.
Refer to text on HP3100 control board.
Check pool temp. Wait until pool needs heat.
HI
High Pressure Switch
High water temp
Call for service.
SH
Temperature sensor
Failure
Call for service.
OP
Temperature sensor
Failure
Call for service.
888
Thermostat reset
Normal operation
Temporary display. Shows for 1-2 seconds when
the unit is first turned on.
Refer to owner’s manual of the remote device.
rhd
Remote heat demand
Remote device is
controlling the unit.
If a remote device is not connected, call for
service.
PST
Push button stuck
Release button is stuck.
If button does not release. Call for service.
PNL
Control not receiving
data from panel
Control communication
problem.
Call for service.
CEL
Panel not receiving data
from control
Control communication
problem.
Call for service.
CHC
Board self-check error
Board Failure
Call for service.
dEF
Defrost Mode
Frost build up on
evaporator coil.
No action required. Unit is defrosting
automatically.
cOP
Coil Sensor
Sensor Failure
Call for Service
cSH
Coil Sensor
Sensor Failure
Call for Service