Page 5 of 20
HEATPRO HEAT PUMP
HP13023770 Rev: E
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Pomona, CA Clemmons, NC Nashville, TN
Tel: 908.351.5400 www.haywardpool.com
Hayward HeatPro Heat Pump Dimensions
MODELS:
HP20654T, HP20654BT, HP20854T, HP20854BT and HP21104T
Hayward HeatPro Heat Pump Specifications
Operating Specification
HP20654T & HP20654BT HP20854T & HP20854BT
HP21104T
Volts
240
240
240
Hertz
60
60
60
Phase
1
1
1
Compressor Maximum Operating Current
17.9A
28A
27A
Compressor LRA
112A
135A
145A
Fan Motor Max Load (Amps)
2.8A
2.8A
2.8A
Fan Motor HP
1/3
1/3
1/3
Minimum Circuit Ampacity
24
36
35
Maximum Fuse Size (Amps)
40
60
60
Refrigerant
R-410A
R-410A
R-410A
Min. Water Flow Rate (GPM)
30
30
30
Max. Water Flow Rate (GPM)
75
75
75
Maximum Water Temperature
104°F
104°F
104°F