With the trippers still in the “on
position” check for 115 – 124 VAC
between terminals E5 and E6 on the
PCB.
If voltage is not correct, replace the PCB.
Otherwise, proceed to Step 6D.
Page 22
Step 7C
Verify 115-125 VAC is present at the
pump receptacle on the bottom of
the Trol.
If voltage is not correct, replace receptacle. Otherwise,
the Trol is working correctly and the pump is where the
problem lies.
Step 7D
6. Pump Not Turning On