6
Controls
Main Switch
AUTO
: For normal operation, the Main Switch should be left in the AUTO position.
In this position the Aqua Rite will produce chlorine according to the "Desired Out-
put %" adjustment setting for the entire filtering/pumping cycle.
SUPER CHLORINATE
: When you have an abnormally high bather load, a large
amount of rain, a cloudy water condition, or any other condition which needs a large
amount of purification to be introduced, put the Main Switch in the SUPER CHLO-
RINATE position. This electronically “super chlorinates” (shocks) the water for 24
hours (filter pump must be on during this time) or until the power has been turned
off, whichever comes first. At the end of the super chlorinate time, be sure to put the
switch back into the AUTO position.
OFF
: The OFF position prevents the Aqua Rite from energizing the electrolytic cell.
In this position there is no chlorine generation. NOTE: To service any of the pool
equipment or the Aqua Rite, turn the power off at the circuit breaker.
Indicator LED's
POWER
When illuminated, the Aqua Rite has input power.
GENERATING
This LED is on steady during normal operation. When flashing, the
pool water is too hot or cold to operate.
SUPER CHLORINATE
Illuminates during super-chlorination. See description
above.
REMOTELY CONTROLLED
When illuminated, indicates that a remote pool auto-
mation control (Hayward/Goldline Pro Logic, Pentair Intellitouch, Polaris Eos, etc.)
is controlling the Aqua Rite--the main switch and "Desired Output %" adjustment
are inactive. When flashing, the Pro Logic, Intellitouch or Eos is in SERVICE or
TIME-OUT mode and the Main Switch and "Desired Output %" adjustment are
active.
NO FLOW
When illuminated, the flow switch has detected no water flowing and
the Aqua Rite has stopped generating chlorine. A flashing LED indicates a 15-60
second time delay period.
CHECK SALT
When flashing, the salt level is low (below 2700 ppm) and Aqua Rite
is generating at low efficiency. When illuminated steady, the salt level is too low and
Aqua Rite has shut down. Before adding large quantities of salt, it is advisable to
have your salt level professionally checked.
HIGH SALT
When illuminated, the salt level is too high and Aqua Rite has shut
down.
INSPECT CELL
A flashing indicator signifies that either the cell efficiency is re-
duced or that it is time for regularly scheduled cell inspection. In either case, inspect
cell and clean if necessary. When illuminated steady, cell efficiency is greatly re-
duced and the Aqua Rite
has stopped producing chlorine. Inspect, clean or replace
if necessary.
9
The Aqua Rite electrolytic cell has a self cleaning feature incorporated into the elec-
tronic control’s logic. In most cases this self cleaning action will keep the cell working
at optimum efficiency. In areas where water is hard (high mineral content) and in pools
where the water chemistry has been allowed to get "out of balance", the cell may require
periodic cleaning. The "Inspect Cell" LED will indicate if cell efficiency is decreased and
servicing is necessary. If the "Inspect Cell" LED remains on after a thorough cleaning,
the cell may be worn and require replacement.
Servicing and Cleaning the Aqua Rite cell
Turn off power to the Aqua Rite before removing the electrolytic cell. Once removed,
look inside the cell and inspect for scale formation (light colored crusty or flaky depos-
its) on the plates and for any debris which has passed through the filter and caught on
the plates. If no deposits are visible, reinstall. If deposits are seen, use a high pressure
garden hose and try to flush the scale off. If this is not successful, use a plastic or wood
tool (do not use metal as this will scratch the coating off the plates) and scrape deposits
off of plates. Note that a buildup on the cell indicates that there is an unusually high
calcium level in the pool (old pool water is usually the cause). If this is not corrected,
you may to have to periodically clean the cell. The simplest way to avoid this is to bring
the pool chemistry to the recommended levels as specified.
Mild Acid Washing:
Use only in severe cases where flushing and scraping will not
remove the majority of deposits. To acid wash, turn off power to Aqua Rite. Remove cell
from piping. In a clean plastic container, mix a 4:1 solution of water to muriatic acid (one
gallon of water to one quart of muriatic acid). ALWAYS ADD ACID TO WATER -
NEVER ADD WATER TO ACID. Be sure to wear rubber gloves and appropriate eye
protection. The level of the solution in the container should just reach the top of the cell
so that the wire harness compartment is NOT submerged. It may be helpful to coil the
wiring before immersing the cell. The cell should soak for a few minutes and then rinse
with a high pressure garden hose. If any deposits are still visible, repeat soaking and
rinsing. Replace cell and inspect again periodically.
Winterizing
The Aqua Rite electrolytic cell and flow detection switch will be damaged by freezing
water just as your pool plumbing would. In areas of the country which experience
severe or extended periods of freezing temperatures, be sure to drain all water from the
pump, filter, and supply and return lines before any freezing conditions occur. The
electronic control is capable of withstanding any winter weather and should not be
removed.
Spring Start-up
DO NOT turn the Aqua Rite on, until the pool water chemistry has been brought to the
proper levels. This information can be found on page 1.